Sealey TP97 Скачать руководство пользователя страница 3

4.  priminG & OperatiOn

5.  maintenanCe

4.1  PrImInG of tHe unIt

 

WarninG! neVer run the pump in an unprimed condition as this will damage the pump and invalidate your warranty.

4.1.1  Before the pump can be used for the first time it must be primed with fuel using the procedure outlined below.

4.1.2  Place the nozzle into an appropriate collecting container and press and hold the trigger.

4.1.3  operate the manual priming lever until fuel emerges from the nozzle. release the trigger.

4.1.4  the pump is now ready to be switched on.

4.1.5 

If the pump is moved from one container to another it must be reprimed before it can be used again.

4.2  normAl oPerAtIon

4.2.1  switch on the pump and remove the filler cap from the container or vehicle tank that is to be filled.

4.2.2  Place the nozzle into the tank opening.

4.2.3  Press and hold the trigger until the desired amount of fuel has been dispensed.

4.2.4  release the trigger, remove the nozzle from the tank and replace the filler cap.

4.2.5  ensure that the delivery nozzle and hose are safely stowed adjacent to the pump ready for the next delivery.

 

danGer!

 clean up any spillage in accordance with regulations governing the handling of diesel fuels.

 

WarninG! 

do not operate the pump unsupervised.

 

WarninG! 

do not allow the pump to run dry. At the end of each delivery the suction filter should always be below the level of the fuel. 

 

WarninG! 

do not let the pump deliver for more than 5 minutes against a closed nozzle in order to avoid exceeding the permitted  

 

  operating temperature.

 

WarninG! 

regularly check the delivery hose and connections for damage in order to avoid leakage of fuel. 

4.3  emerGencY oPerAtIon

4.3.1  In the event of a power failure it is possible to manually pump very small quantities of fuel using the procedure outlined below.

4.3.2  Place the nozzle into the container or vehicle tank and press and hold the trigger.

4.3.3  operate the manual priming lever to deliver the fuel.

4.3.4  When the delivery is complete release the trigger and remove the nozzle.

4.3.5  safely stow the delivery tube and nozzle and replace the filler cap on the container or vehicle tank.

4.4  demountInG And remountInG tHe PumP

4.4.1  When demounting the pump in order to place it onto another container or for storage observe the following procedure.

4.4.2  take suitable precautions to clear up minor spills of fuel that may occur when demounting the pump.

4.4.3  switch the pump off and disconnect it from the battery or unplug it from the mains power supply.

4.4.4  Before the pump can be unscrewed from the fuel container the delivery hose must be disconnected. 

4.4.5  to empty the fuel remaining in the delivery hose firstly place the nozzle into a collection container and hold the trigger open.

4.4.6  Keeping the trigger open begin to loosen the union where the hose is connected to the pump. As the union becomes loose and air  

 

 

enters the pipe the excess fuel should flow into the container. Keep the disconnected end of the hose at a high level and the container   

 

at a low level so that all the fuel is emptied from the hose.

4.4.7  unscrew the pump from the threaded connector on the fuel container and slowly remove the pump with the suction hose and filter  

 

 

attached allowing the fuel to run out completely.

4.4.8  If the pump is then mounted to another fuel storage container it must be primed first before switching on.

4.4.9  If the pump is to be stored even for a short period of time the pump and its hoses should be laid into a clean oil tray in order for all  

 

 

excess fuel to drain out. the pump and hoses should be cleaned and stored in a well ventilated store suitable for product that handles   

 

fuel.

5.1 

the pump has been designed for low maintenance. should any problems occur return the unit to your local sealey dealer.

5.2 

clean the entire installation and inspect all piping connections for leaks. rectify any damage immediately.

5.3 

Inspect the filter at the end of the suction tube every time the tank is refilled.

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

impOrtant: 

no liability is accepted for incorrect use of this product. 

WarrantY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

infOrmatiOn:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole uK distributor, sealey Group, 

Kempson Way, suffolk Business Park

Bury st. edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

tP97, tP9724, tP97230    Issue: 3 - 22/03/10

Содержание TP97

Страница 1: ...UE neutral wire to the neutral terminal N d After wiring check that there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight Double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated a...

Страница 2: ... joint with hose clamp 7 3 2 2 Cut the suction hose to length bearing in mind that the pump may be mounted to more than one container and that the filter must be always be under the surface of the fuel even when the fuel level is low 3 2 3 Slide the second hose clamp 5 over the end of the suction hose Push the suction hose over the suction union on the pump 4 Slide the hose clamp up onto the joint...

Страница 3: ...er or for storage observe the following procedure 4 4 2 Take suitable precautions to clear up minor spills of fuel that may occur when demounting the pump 4 4 3 Switch the pump off and disconnect it from the battery or unplug it from the mains power supply 4 4 4 Before the pump can be unscrewed from the fuel container the delivery hose must be disconnected 4 4 5 To empty the fuel remaining in the ...

Страница 4: ...25 and leave your full name and address including postcode 01284 757500 01284 703534 sales sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk Web email Original Language Version ITEM PART No DESCRIPTION 1A 179 23710 930 PUMP 12V WITH CABLE AND CASING 1B 179 23720 930 PUMP 24V WITH CABLE AND CASING 1C 179 23731 930 PUMP ...

Отзывы: