Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note
: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on [email protected] or 01284 757505.
Important
: No Liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
8. TROUBLESHOOTING
Problem
Possible causes
Solution
Motor not turning
Lack of electric power
Set the starting handle to position ON
Reset the external residual current circuit-breaker
Check the electrical connections
Fuses burned out
Replace the fuses in the electric panel
Faulty switch on the electric panel
Change the switch
Motor problems
If the rotor is jammed, dismount and check for damage and
obstructions, then remount
Contact the Service Department
Motor will not start with the nozzle
closed
Electric voltage too low
Check that the voltage is not more than 5% below the
nominal voltage
L
ow or no flow rate
Excessive suction pressure
Lower the CUBE with respect to the tank or increase the
diameter of the tubing
High loss of head
Use shorter tubing or of greater diameter
Suction tube resting on the bottom of
the tank
Raise the suction tube
Low level in the suction tank
R
efill the tank
Air entering the suction tube or in the
pump
Check the connections seal in the tubing and the level of
diesel fuel in the tank
Motor low rotation speed
Check the voltage at the motor.
Adjust the voltage and/or use cables of greater cross-section
Check valve blocked
Clean or replace
T
ank filter clogged
C
lean the filter
P
ump filter clogged
C
lean the filter
Fluid leaking
Check the seal of the connections and the condition of the
rubber tubes
Meter chamber obstructed
Clean the meter chamber
M
eter accuracy not sufficient
Air in the suction line
Check the sels of the connections
Measuring chamber dirty
Clean the meter measuring chamber
Original Language Version
© Jack Sealey Limited
TP955.V2 Issue:2 (H,F) 12/10/21