background image

p

WARNING! 

Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and regulations.

3

Familiarise yourself with application and limitations, as well as the potential hazards peculiar to the pump.

p

WARNING!

Disconnect the pump from the battery before changing accessories, servicing or performing any maintenance.

3

Maintain the pump in good condition. Keep the pump clean.

3

Replace or repair damaged parts (use an authorised service agent). 

Use genuine parts only. Non authorised parts may be dangerous and will 

invalidate the warranty.

3

If the bottom of the liquid container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to 

operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.

3

In flood situations, user is responsible for ensuring that appropriate back up procedures, alarms etc are correctly installed in case of pump failure.

3

In swimming pool, fish ponds, etc, ensure location is clear of people and animals (including removal of fish from pond). Note: this pump is not 

designed for continuous use in a fish pond or similar water feature or display.

8

DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or personal injury.

8

DO NOT use the pump for any purpose other than for which it is designed.

8

DO NOT use to pump septic tanks or settling pits. 

8

DO NOT operate pump out of water. The pump pick up area must be completely submerged during operation.

8

DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.

8

DO NOT carry the pump by its electrical cable, or outlet pipe. 

3

When not in use remove battery clips from terminals. Rinse pump, drain out any liquid and store in a frost free, safe location.

p

WARNING! 

Whilst the pump may be used in dirty water, it is not to be used for such water containing large particles e.g. mud, weed etc.

p

WARNING! 

DO NOT allow uncontrolled discharge of contaminated water/harmful chemicals thus polluting the environment.

INSTRUCTIONS FOR:

SUBMERSIBLE TRANSFER PUMP

Model:

TP94

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATIONS

Self priming portable pump for use with diesel, various chemicals, and fresh or dirty water. Suitable for re-fuelling/fluid transfer of plant, agricultural

and marine equipment on site. The pump is supplied with a 3mtr outlet hose and stainless steel nozzles, plus a 4mtr battery cable with clips. 

Flow rate at hose end:

16.5 ltr/m

Voltage:

12V

Current:

4.5amp / DC

Pressure:

15psi / 1bar

Diameter:

53.5mm

Length:

145mm

Weight:

0.6kg

Duty Cycle:

15mins  

3. CONTENTS 

Unpack the product and check the contents.

Ensure that there is no damage. If any problem is noted, 

contact your supplier immediately. 

A .......... 3 metre outlet hose + stainless steel nozzle

B .......... Motor

C.......... Impeller guard

D.......... Filter

E .......... End cap

F .......... Battery clips

G.......... 4 metre battery cable

H.......... Seal cap

TP94 - 2 - 240703