Sealey TM105 Скачать руководство пользователя страница 3

TM105      Issue No: 2(I) - 17/06/14

© Jack Sealey Ltd

Original Language Version  

1) AC  DC

        AC (alternating current) 

 

and DC (direct current).

2)

                   Minus sign.

3) 1.8.8.8

     2000 count (0 to 1999) measurement 

 reading. 

4)  AUTO

         AutoRange mode.

5)  REL

            Relative mode.

6)

                     Diode test mode. 

7)  •))) 

           Audible Continuity.

8)  HOLD

        Data Hold mode. 

9)  °C, °F, µ, m, V, A, K, M, Ω,

 Units of measure list.

10)  MAX

         MAX hold mode.

 

3. SPECIFICATION

Clamp size ................................. Opening 1.2” (30mm) approx.

Diode Test .................................. Test  current of 0.3mA typical; Open circuit voltage 1.5V DC typical.

Continuity Check ....................... Threshold <150Ω; Test current < 0.5mA.

Low Battery Indication ............... “      ” is displayed.

Overrange Indication ................. “OL”  is displayed.

Measurements Rate .................. 2 per second, nominal.

Input Impedance ........................ 10MΩ (VDC and VAC).

Display ....................................... 2000 counts LCD.

AC Current................................. 50-60Hz (AAC).

AC Voltage bandwidth  .............. 50-60Hz (VAC).

Operating Temperature .............. 41 to 104oF (5 to 40°C).

Storage Temperature ................. -4 to 140oF (-20 to 60°C).

Operating Humidity .................... Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C).

Storage Humidity ....................... <80%. 

Operating Altitude ...................... 7000ft. (2000meters) maximum.

Over voltage .............................. Category III 600V.

Battery ....................................... One 9V Battery.

Auto OFF ................................... approx. 15 minutes 

Dimensions/Weight .................... 197x70x40mm/183g

For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, 

portable equipment, etc., with transient overvoltages less than Overvoltage Cat. III

 

1

2

3

4

5

6

7

8

9

10

Function

Range

Accuracy (% of reading)

AC Current

(50/60Hz)

2.000AAC

± (2.5 % + 10 digits)

20.00AAC

± (2.5 % + 4 digits)

200.0AAC

± (2.5 % + 4 digits)

400.0 AAC

± (3 % + 4 digits)

DC Voltage

200.0 mVDC

± (0.8% + 2 digits)

2.000 VDC

± (1.5% + 2digits)

20.00 VDC
200.0 VDC
600.0 VDC

± (2 % + 2 digits)

AC Voltage

200.0 mVAC

± (1.5% + 35 digits)

2.000 VAC

± (1.8% + 8 digits)

20.00 VAC
200.0 VAC
600.0 VAC

± (2.5% + 8 digits)

Resistance

200.0 Ω

± (1.0% + 4 digits)

2.000KΩ

± (1.5% + 2 digits)

20.00KΩ
200.0KΩ

2.000MΩ

± (2.5% + 3 digits)

   20.00MΩ

± (3.5% + 5 digits)

Содержание TM105

Страница 1: ...ter carefully in a safe dry childproof location out of direct sunlight Storage temperature range 20 C to 60 C ALWAYS turn off the power and disconnect the test leads before opening the doors to replace the fuse or batteries The user shall ensure that test probes are correctly selected in order to prevent danger Probes shall be selected to ensure that adequate barriers guard against inadvertent han...

Страница 2: ...ary Function Switch 5 Data Hold Button 6 Back Light Button 7 LCD Display 8 Mode Select Button 9 Range Button 10 Max Hold Button 11 Com Input Jack 12 V Ω CAP TEMP Hz Jack 13 Battery Cover 1 4 BATTERY INSTALLATION WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery cover Disconnect the test leads from the meter Open the battery cover by lo...

Страница 3: ...5 to 40 C Storage Temperature 4 to 140oF 20 to 60 C Operating Humidity Max 80 up to 87 F 31 C decreasing linearly to 50 at 104 F 40 C Storage Humidity 80 Operating Altitude 7000ft 2000meters maximum Over voltage Category III 600V Battery One 9V Battery Auto OFF approx 15 minutes Dimensions Weight 197x70x40mm 183g For indoor use and in accordance with Overvoltage Category II Pollution Degree 2 Cate...

Страница 4: ...4V to 0 7V Reverse voltage will indicate OL Shorted devices will indicate near 0mV and an open device will indicate OL in both polarities For Continuity tests if the resistance is 150Ω a tone will sound 4 5 Non Contact AC Voltage Measurements WARNING Risk of Electrocution Before use always test the Voltage Detector on a known live circuit to verify proper operation 4 5 1 Touch the probe tip to the...

Страница 5: ...copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address including postcode 01284 757500 01284 703534 sales sealey co uk www sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories an...

Отзывы: