1.1.  PERSONAL PRECAUTIONS

 

When using this multimeter, please observe all normal safety rules concerning:

 

Protection against the dangers of electrical current.

 

Protection of the meter against misuse.

 

Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must  

 

be replaced with genuine Sealey leads with the same electrical ratings. Failure to do so will invalidate the warranty.

 

DO NOT

 use leads if damaged or if the wires are bared in any way. 

1.2.   GENERAL SAFETY INSTRUCTIONS

 

Familiarise yourself with the application and limitations of the multimeter as well as the potential hazards.

 

 

IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.

 

USE EXTREME CAUTION

 when working with high voltages.

 

When the meter is connected to a circuit, 

do not

 touch unused meter terminals.

 

When the magnitude of the value to be measured is unknown, set the range selector to the highest value available.

 

Before commencing testing, follow instructions below and select the correct input sockets, function and range on the 

 multimeter.

 

Before rotating the rotary switch to change functions, disconnect the test leads from the circuit under test.

 

Take care when working with voltages above 35V DC or 25V AC rms. These voltages are considered a shock hazard.  

 

Keep fingers behind the probe barriers whilst measuring.

 

DO NOT

 test voltages above 600V - the circuitry of the multimeter may be destroyed.

 

WARNING! NEVER 

connect the multimeter to a voltage source / live circuit when the rotary switch is set to any other  

 

function apart from Voltage testing.

 

WARNING! NEVER 

perform resistance, transistor, diode or continuity measurements on live circuits.

 

ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests.

 WARNING! 

Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to  

 

the recessed electrical contacts. Other means should be used to ensure that the terminals are not “live”.

 

DO NOT 

use the multimeter in a potentially explosive atmosphere.

  

NEVER

 operate the meter unless the back cover and the battery and fuse doors are in place and fastened securely.

 

If any abnormal readings are observed, the multimeter must be checked out by an authorised technician.

 

When not in use, store the multimeter carefully in a safe, dry, childproof location out of direct sunlight. 

 

Storage temperature range -20

°

C to 60

°

C.

 

ALWAYS

 turn off the power and disconnect the test leads before opening the doors to replace the fuse or batteries.

 

The user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected  

 

to ensure that adequate barriers guard against inadvertent hand contact with live conductors under test and that  

 

probes have minimal exposed probe tips.  Where there is a risk of the probe tip short circuiting with other live  

 

conductors under test, it is recommended that the exposed tip length shall not exceed 4mm.

NOTE:The warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and

 

situations that may occur. It must be understood that common sense and caution are factors which cannot be  

 

built into this product, but must be applied by the operator.

1.3.  SAFETY SYMBOLS.

 

This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer 

 

to an explanation in the Operating Instructions to avoid personal injury or damage to the meter.

 

This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death  

 

or serious injury.

 

This CAUTION symbol indicates a potentially hazardous situation, which if not avoided, may result damage  

 

to the product.

 

 

This symbol, adjacent to one or more terminals identifies them as being associated with ranges that may,  

 

in normal use, be subjected to particularly hazardous voltages. For maximum safety, the meter and its test  

 

leads should not be handled when these terminals are energized.

 

 

This symbol indicates that a device is protected throughout by double insulation or reinforced insulation.

WARNING

CAUTION

INSTRUCTIONS FOR:

PROFESSIONAL AUTO-RANGING DIGITAL 

CLAMP METER NCVD - 6 FUNCTION 

MODEL No:

 

TM105

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

TM105      Issue No: 2(I) - 17/06/14

© Jack Sealey Ltd

Original Language Version  

 

 

 

Содержание TM105

Страница 1: ...ter carefully in a safe dry childproof location out of direct sunlight Storage temperature range 20 C to 60 C ALWAYS turn off the power and disconnect the test leads before opening the doors to replace the fuse or batteries The user shall ensure that test probes are correctly selected in order to prevent danger Probes shall be selected to ensure that adequate barriers guard against inadvertent han...

Страница 2: ...ary Function Switch 5 Data Hold Button 6 Back Light Button 7 LCD Display 8 Mode Select Button 9 Range Button 10 Max Hold Button 11 Com Input Jack 12 V Ω CAP TEMP Hz Jack 13 Battery Cover 1 4 BATTERY INSTALLATION WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery cover Disconnect the test leads from the meter Open the battery cover by lo...

Страница 3: ...5 to 40 C Storage Temperature 4 to 140oF 20 to 60 C Operating Humidity Max 80 up to 87 F 31 C decreasing linearly to 50 at 104 F 40 C Storage Humidity 80 Operating Altitude 7000ft 2000meters maximum Over voltage Category III 600V Battery One 9V Battery Auto OFF approx 15 minutes Dimensions Weight 197x70x40mm 183g For indoor use and in accordance with Overvoltage Category II Pollution Degree 2 Cate...

Страница 4: ...4V to 0 7V Reverse voltage will indicate OL Shorted devices will indicate near 0mV and an open device will indicate OL in both polarities For Continuity tests if the resistance is 150Ω a tone will sound 4 5 Non Contact AC Voltage Measurements WARNING Risk of Electrocution Before use always test the Voltage Detector on a known live circuit to verify proper operation 4 5 1 Touch the probe tip to the...

Страница 5: ...copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address including postcode 01284 757500 01284 703534 sales sealey co uk www sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories an...

Отзывы: