Sealey TA302 Скачать руководство пользователя страница 2

3.  features

4.  sPecification

input limits

function

terminal

input limit

ac volts

V - 

Ω 

- rpm

  

600V ac rms

dc Volts

1000V dc

Frequency

V - 

Ω 

- rpm

500V ac/dc

ohm (resistance)

V - 

Ω 

- rpm

250V ac/dc

diode
ac/dc mA

mA

320mA ac/dc

ac/dc 20A

20A

*20A ac/dc

RPM

V - 

Ω 

- rpm

500V ac/dc

duty Cycle (%)
dwell Angle

contents/layout

:

1.   lCd display

2.   Alternate Function 

3.   dwell 

4.   RPM Mode Button - Stroke 

(4/2(dIS)

5.   Rotary selector Switch

6. 

20a

 Terminal

7.  

ma

 Terminal

8.   Range Button

9.   Backlight

10.   Hold Button

11. Volts, 

Ω, 

Hz, %, RPM,dWell and    

 TeMP 

Terminal

12.  CoM Terminal

13.  Inductive Coupler

14. Thermocouple

15.  Test Probes

   fig.1

 

‰

 

Warning! Do not make current 

measurements between 1a and 20a 

for longer than 30 seconds in every 15 

minutes. exceeding 30 seconds may 

cause damage to the meter and test 

probes.

 

‰

 

Warning! ohms cannot be measured if 

a voltage is present. only measure in non 

powered circuits.

Dc voltage (auto ranging)

range

resolution

accuracy

32mV

0.1mV

± 1.2% of rdg +1 dgt

3.2V

1mV

32V

10mV

320V

100mV

1000V

1V

Input Impedance: 10MΩ.

Maximum Input: 1000Vdc or 750Vac rms 

 

ac voltage (auto ranging)

range

resolution

accuracy

3.2V

0.1mV

± 2.0% of rdg +4 dgt

32V

1mV

320V

10mV

750V

100mV

Input Impedance: 10MΩ.

Frequency Range: 50 to 60Hz

Maximum Input: 1000Vdc or 750Vac rms  

Duty cycle

range

resolution

accuracy

1.0%~90.0%

0.1%

± 2.0% of rdg +5 dgt

Pulse Width: >100us, <100ms

overload Protection: 500Vdc or RMS ac  

Dwell angle

no. cyl

range

resolution

accuracy

4

0~90°

0.1°

± 2.0% of rdg +5 dgt 

5

0~72°

6

0~60°

8

0~45°

overload Protection: 500Vdc or RMS ac

temperature

range

resolution

accuracy

-20~750°C

0.1°C

± 3.0% of rdg +2°C

-4~1400°F

0.1°F

± 3.0% of rdg +4°F

Sensor: Type K Thermocouple

Input Protection: 250Vdc or Vac rms 

current

range

resolution

accuracy

32mA

0.1mA

dC ± 2.0% of rdg +1dgt
AC ± 2.5% of rdg +4dgt

320mA

1mA

dC ± 2.0% of rdg +1dgt
AC ± 2.5% of rdg +4dgt

10A

10mA

dC ± 3.0% of rdg +3dgt
AC ± 3.5% of rdg +4dgt

Frequency Response: 50 to 60Hz
Input Protection: Fast acting ceramic fuse on mA and 10A input

resistance (auto ranging)

range

resolution

accuracy

320

0.1

± 1.5% of rdg +3 dgt

3.2k

1

32k

10

3.2M

1K

± 2.5% of rdg +3 dgt

32M

10K

± 5.0% of rdg +5 dgt

overload Protection: 250Vdc or RMS ac

frequency

range

resolution

accuracy

320Hz

0.1Hz

± 1.0% of rdg +4 dgt

3200Hz

1Hz

32KHz

10Hz

Sensitivity: 3.5V rms min.

overload Protection: 500Vdc or rms ac

Diode test

range

resolution

accuracy

0.6mA typical (Vf=0.6V)

1mA

± 10% of rdg +3 dgt

open Circuit Voltage: 3Vdc Typical

overload Protection: 250Vdc or rms ac

TA302 Issue 3 (HF) 02/10/18

Original Language Version

© Jack Sealey limited

Содержание TA302

Страница 1: ...g to insert transistors for testing ensure that the test probes have been disconnected 9 9 Components should not be connected to the transistor socket when taking voltage measurements with the test probes 8 8 DO NOT test voltages above 600V ac or 1000V dc the circuitry of the multimeter will be destroyed WARNING NEVER connect the multimeter to a voltage source live circuit when the rotary switch i...

Страница 2: ...V Input Impedance 10MΩ Frequency Range 50 to 60Hz Maximum Input 1000Vdc or 750Vac rms Duty Cycle Range Resolution Accuracy 1 0 90 0 0 1 2 0 of rdg 5 dgt Pulse Width 100us 100ms Overload Protection 500Vdc or RMS ac Dwell Angle No Cyl Range Resolution Accuracy 4 0 90 0 1 2 0 of rdg 5 dgt 5 0 72 6 0 60 8 0 45 Overload Protection 500Vdc or RMS ac Temperature Range Resolution Accuracy 20 750 C 0 1 C 3 ...

Страница 3: ...n to toggle between 4 stroke and 2 stroke DIS Distributerless Ignition System 5 5 2 Press and hold for two seconds to toggle between Negative and Positive Trigger slope 5 5 3 Press the button repeatedly to adjust the trigger level if the meter reading is to high or unstable Note The Trigger level has five steps and is different for each function combination 5 6 Backlight button fig 1 9 5 6 1 To tu...

Страница 4: ...y mode a complete circuit will beep continuously if open circuit there will be no beep 5 11 Frequency Hz 5 11 1 Insert the black test probe into the negative COM terminal and the red test probe into the positive main positive terminal fig 1 10 terminal 5 11 2 Turn the rotary switch to either of the Hz positions 320Hz 3200Hz 32kHz 5 11 3 Connect the negative COM test probe to ground 5 11 4 Connect ...

Страница 5: ...emove the blown fuse Be careful not to damage the PCB 6 2 4 Install the new fuse into its holder Join the casing back together and secure with screws Note Always use a fuse of the correct size and value 0 5A 250V fast blow for the 320mA range 20A 250V fast blow for the 20A range 6 2 5 Replace the battery and cover and secure with the screws WARNING To avoid electric shock do not use the meter unti...

Отзывы: