Sealey TA060 Скачать руководство пользователя страница 3

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

4.7.9.   

To exit SET UP mode and save your settings press HOLD once.

4.7.9.1.   If you continue to press the A/C button in edit mode the initialization/reset screen appears. If you now press the A/C button again your personal  

  settings will be lost and the screen reverts to the original factory settings.

5.  OPERATION

 

‰

  

WARNING: In strong wind conditions it is essential that the wind muffler is used to avoid picking up unnecessary background  

  noise, see fig.3 below.

5.1. 

  

Switch the meter on by pressing the ON/OFF button.

5.2. 

  

Press the LEVEL/REC button up to four times to cycle through to the  best level for the measurement task in hand. Keep an eye on the  

 

OVER and UNDER indicators at the top of the LCD display. Select a level where these indicators are off.

5.3. 

  

Using the A/C button select ‘dBA’ for recording general sound levels in relation to human hearing and ‘dBC’ for measuring the sound  

 

level of general acoustic material. 

5.4. 

  

Using the F/S button select either FAST sampling for instant sound and SLOW sampling for average sound level.

5.5. 

  

Using the MAX/MIN button select whether you require to monitor the maximum sound level predominant at the time of measuring or  

 

the minimum sound level.

5.6. 

  

Begin measuring sound levels by either using the unit held in your hand or mount it on a tripod. The meter should be 1 to 1.5 metres  

 

away from the sound source.

5.7. 

  

Record sound levels as required as described in Data Reading Function section.

6.  MAINTENANCE

 

8

  

DO NOT

 store or operate the meter at high temperature or in conditions of high humidity.

6.1. 

  

If the meter is not to be used for long periods of time, remove the battery to avoid harmful liquid leakage.

6.2. 

  

Keep microphone dry and avoid severe vibration.

6.3. 

  

When the battery symbol shows on the readout replace the 9V battery (PP9).

Original Language Version

© Jack Sealey Limited

TA060 Issue:2 (H,F) 08/12/20

BATTERY REMOVAL

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products 
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack 
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

Отзывы: