  2.  INTRODUCTION & SpECIFICATIONS

All our Supermig® models are suitable for welding with CO², Argon or CO²/Argon mix. Each uses a Forced Air Cooling System to slow transformer heating in order 

to increase duty cycle and a non-live torch to prevent the risk of accidentally striking an arc. Model Nos. SUPERMIG255 / 275 are supplied with an industrial Argon/

CO² regulator. A contract for the supply of gas should be arranged with your local gas distributor.

1.3

  VOLTAGE BETwEEN ELECTRODE hOLDERS OR TORChES.

 

Working with more than one welding machine on a single piece or on pieces that are connected electrically may generate a dangerous amount of no-load   

 

voltage between the two electrode holders or torches, the value of which may reach double the allowed limit. Measuring instruments should be used  to    

 

determine the existence of a risk and suitable precautions taken as detailed in section 5.9 of the IEC TECHNICAL SPECIFICATION OF CLC/TS 62081.

1.4

  ELECTROMAGNETIC INTERFERENCE. 

 

The electromagnetic fields generated by the welding process may interfere with the operation of electrical and electronic equipment. Users of vital electronic  

 

and electrical devices such as pacemakers and respirators are advised not to remain in the viscinity of an operating welding machine. If in doubt seek  

 

 

medical advice before entering a welding area. Users of such devices should not operate the welding machine. This welder complies with the requirements  

 

of the technical standard for the use of this type of product, only and exclusively in industrial environments and for professional purposes. It is not  

 

 

guaranteed to meet electronic compatibility requirements in the home.

1.5

  GAS SAFETY 

 

Store gas cylinders in a vertical position only and ensure the storage area is correctly secured.

 

DO NOT

 store gas cylinders in areas where temperature exceeds 50°C. 

DO NOT

 use direct heat on a cylinder. Always keep gas cylinders cool.

 

DO NOT

 attempt to repair or modify any part of a gas cylinder or valve, and 

DO NOT

 puncture or damage a cylinder.

 

DO NOT

 obscure or remove any official labels from a cylinder. Always check the gas identity before use. Avoid getting gas cylinders oily or greasy.

 

DO NOT 

try to lift or handle cylinder by its cap, guard or valve. Always keep caps and guards in place and close valve when not in use.

 

The gas cylinder is heavy, use mechanical lifting equipment. Ensure the cylinder is correctly situated on the welder base stand and secured with chain.

1.6

  RISK ASSESSMENT

 

Where welding is unavoidable in awkward situations such as in confined spaces, in environments with increased risk of electic shock, and in the presence of  

 

inflamnable or explosive materials, a risk assessment must be carried out by an experienced and qualified expert professional in consultation with providers  

 

of emergency services to ensure that operations are carried out in the safest possible way. 

Model

:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SUpERMIG255

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SUpERMIG275

welding Current

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   40-250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-270A

wire Capacity

: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15kg

Duty

 

Cycle

:   . . . . . . . . . . . . . . . . . . . . . . 100% @ 91A, 60% @ 118A, 20% @ 205A   . . . . . . . . . . . . . . . . . . . . . . . . . .100% @ 112A, 60% @ 146A, 20% @ 255A

Cooling

 

System

:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Forced Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Forced Air

Spot welding Timer

: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes

Gas Type

: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CO², Argon, CO²/Argon Mix   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CO², Argon, CO²/Argon Mix

Torch

:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Euro Non-Live - Binzel®MB24   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Euro Non-Live - Binzel®MB24

power Input

:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 1ph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph

Absorbed power

:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.7kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6kW 

Case Size

:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Large 

Net weight

:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92kg

  3.    RATINGS pLATE SYMBOLS

Detailed technical data relative to the performance of the machine is located on the back panel. 

please note

 that the ratings plate shown below (fig.1) is an 

example only intended to assist with the explanations of symbols. To determine the correct technical values of the machine in your possession, you must refer to 

the data plate on that machine and the specifications shown above.

fig.1

Original Language Version

© Jack Sealey Limited 2013

SUPERMIG255, SUPERMIG275     Issue: 2 (SP)- 28/08/13

Содержание SUPERMIG255

Страница 1: ...INSTRUCTIONS FOR SUPERMIG WELDERS SUPERMIG255 SUPERMIG275 MODEL No s Jack Sealey Limited 2013 SUPERMIG255 SUPERMIG275 Issue 2 SP 28 08 13 ...

Страница 2: ...welding fumes from near the arc The risk should be assessed by a Health and Safety professional in relation to the exposure limits for the welding fumes which will depend on their composition concentration and the exposure time IMPORTANT BEFORE USING THIS PRODUCT PLEASE READ THE INSTRUCTIONS CAREFULLY MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS WARNINGS AND CAUTIONS THIS PRODUCT SHOULD ONLY BE USED F...

Страница 3: ...where temperature exceeds 50 C DO NOT use direct heat on a cylinder Always keep gas cylinders cool DO NOT attempt to repair or modify any part of a gas cylinder or valve and DO NOT puncture or damage a cylinder DO NOT obscure or remove any official labels from a cylinder Always check the gas identity before use Avoid getting gas cylinders oily or greasy DO NOT try to lift or handle cylinder by its...

Страница 4: ...ed adaptor or CO cylinder Take the glossy black plastic gas pipe supplied and push the free end fully onto the regulator gas outlet See fig 6 Note The regulator supplied may differ from that illustrated 5 5 4 Screw the brass fitting on the other end of the gas pipe onto the gas inlet fitting on the rear of the welder See fig 7 5 5 5 Close the regulator by turning the adjusting knob anti clockwise ...

Страница 5: ...CONTACT TIP OF THE TORCH MATCH THE DIAMETER AND TYPE OF WIRE TO BE USED AND ARE FITTED CORRECTLY 6 setting up the wire feed fig 9 fig 10 6 1 6 With the carrier roller and key reassembled as shown in fig 13B orientate the carrier so that the keyway in the carrier itself is aligned with the key on the wire feed drive shaft as shown in fig 12 Slide the carrier fully onto the drive shaft and fix it in...

Страница 6: ...light comes on when overheating occurs and cuts off the power supply it will reset automatically within a few minutes after cooling down IMPORTANT Should you have no welding experience we recommend you seek training from an expert source to ensure your personal health safety You must familiarise yourself with welding applications and limitations and specific potential hazards peculiar to welding G...

Страница 7: ...r fig 18 10 MAINTENANCE WARNING Ensure the unit is disconnected from the mains power supply before performing any maintenance or service 10 1 Regularly check all welding cables and secondary terminals to ensure they are in good order and connected correctly also check during welding to ensure they are not overheating 10 2 Check that the gas hose connections are tight and that there are no gas leak...

Страница 8: ...igh Weld speed too low Increase power and wire speed Move torch slower and weave a little more 12 Weld bead too wide Weld current too high Weld speed too low Arc too long Decrease power and wire speed Move torch faster and weave less Bring torch closer to workpiece 13 Poor penetration Weld current too high Arc too long Increase power and wire speed Bring torch closer to workpiece 14 Excessive pene...