Sealey STW291 Скачать руководство пользователя страница 2

5.  OPERATION

STW291     Issue No.1    28/06/12

Original Language Version

© Jack Sealey Limited

NOTE: ENERGY SAVINGS FUNCTION:

 

If left on and unused, the torque adaptor will turn off  

 

automatically after a period of 4 minutes.   

5.1 

PREPARATION: 

5.1.1  Unscrew the battery cover and install the two batteries  

 

supplied as shown below, ensuring the correct polarity  

 

as indicated in fig.1A. Refix the battery cover as shown  

 

in fig.1B.  

5.4.1  This value can then be stored by pressing the  “ M/u “  

 

button. Once the value is stored, taking 2 to 3 secs, the  

 

display will revert to “ 000.0 “.

5.4.2  If you attempt to store a torque value that is below the  

 

minimum value or above the maximum value defined in  

 

the specification, the abbreviation 

“Erro”

 will be shown  

 

on the display. After 1 second, the torque adaptor will  

 

revert to torque measuring mode. The preset value will  

 

not have been stored, and the warning indicators will  

 

not work until a valid value has been stored. 

5.5

 

(b) ANGLE setting mode

:

 

NOTE: Before setting the angle, the adaptor (with  

 

wrench and socket attached) should be positioned onto  

 

the fitting to be tightened so that the adaptor has a  

 

datum starting point against which to set the angle.

5.5.1  To set the angle value, press the  “         “  button for 2  

 

seconds. (NOTE: If no buttons are then pressed, the  

 

display will revert to zero after 6 seconds). 

5.5.2  The display will initially show “ SET “ for 1 second and  

 

then revert  to the last saved angle or “ 0° “. ( To zero  

 

the last saved angle setting press the  “       “  button).  

 

By repeatedly pressing the “      “ button, the angle  

 

value will be progressively increased until the required  

 

angle value is reached. 

5.5.3  This value can then be stored by pressing the  “ M/u “  

 

button. Once the value is stored, taking 2 to 3 secs, the  

 

display will revert to “ 0° “.

5.5.4  When in ANGLE measuring mode the direction of 

 

rotation of the adaptor can be changed from clockwise  

 

(CW)  to counterclockwise (CCW) and back again by  

 

pressing the “ M/u “ button  

5.6 

Mode Select:

 

5.6.1   The “TRACK” mode is the default when the torque  

 

adaptor is switched on. In “TRACK” mode the display  

 

shows the reading in real time during the torque  

 

process both when the pressure is increased or  

 

released. When the programmed value is reached the  

 

unit signals both audibly and visually whilst the adaptor  

 

is under pressure. As soon as the pressure is released  

 

the display reverts to zero

5.6.2  Press the “M/u” button to shift into “PEAK” mode. The  

 

display shows “peak” in the top left of the display. 

5.6.3   In “PEAK” mode the display will always hold the current  

 

value reached, even if the pressure is slightly released.  

 

When the programmed value is achieved, the unit  

 

signals both audibly and visually and the value shown  

 

on the display will begin to flash after approx. one  

 

second. If further pressure is applied after the 

 

programmed value has been reached the unit assumes  

 

that further torque is to be applied up to the current  

 

programmed value and the display again shows torque  

 

ascending from zero. Alternatively, you can zero the  

 

display and apply the programmed torque to another  

 

fixing. 

5.7 

Turning the display illumination on/off.

  

The display illumination can be turned on prior to or  

 

after programming the torque. In order to do this, press  

 

and hold the “        “ button for 2 Secs.

5.8 

OPERATION: 

5.8.1  When you approach /- 5 Nm of the programmed  

 

torque value the unit will beep intermittently.

5.8.2  When you approach /- 2 Nm of the programmed  

 

value the unit will emit a quicker sound sequence.

    

fig.1

5.1.2  Press the ON/OFF button once to turn the meter on.  

 

The display will initially show four zeros (“0000”) before   

 

reverting to a “0.0” torque reading.

5.1.3  To select the required unit of measurement, press and  

 

hold the “M/u” button for 4 seconds. As soon as the  

 

display jumps to the next unit of measurement let go of  

 

the button. Repeat this process until the display shows  

 

the unit you require. ( Nm / lb.ft / lb.in ).

5.1.4  Ascertain the correct size and type of socket for the 

 

fixing to be tightened and attach it to the square drive  

 

connection (1/2” ) at the base of the adaptor.

5.1.5  Insert the required ratchet wrench/drive bar into the  

 

socket at the top of the adaptor. Do not use a tool that  

 

will allow you to apply excessive force through the  

 

adaptor.

5.2 

SELECTING THE TORQUE OR ANGLE 

 

MEASUREMENT MODE: 

5.2.1  By default, the adaptor switches on in Torque 

 

Measurement Mode. Press “          “  button to switch 

 

to Angle Measurement Mode or back into Torque 

 

Measurement Mode when required.

5.3 

SETTING THE TORQUE OR ANGLE VALUE: 

5.3.1  In order to set the torque or angle value, press the 

  

“      “  button for 2 seconds. NOTE: If no buttons are  

 

then pressed, the display will revert to zero after 6  

 

seconds.

5.4

 

(a) TORQUE setting mode:

 The display will initially  

 

show “ SET “ for 1 second and then revert to the last  

 

saved torque or “ 000.0 “. The first digit of this value 

 

( “000.0“ ) will be flashing, indicating that the value can  

 

now be set/altered. ( To zero the last saved torque 

 

setting press the  “       “  button ). By repeatedly  

 

pressing the “      “ button, the value of the flashing 

 

digit will be progressively increased. When the  

 

required value is reached, press the  “        “  button to  

 

move to the next digit. Repeat this process for all digits     

 

(ones, tens, hundreds etc) until the desired value has  

 

been set. 

 

Отзывы: