background image

• 

8

 •

6. 

Plug the charger power cord into an AC electrical wall outlet. Make sure to place the 

charger on a dry, non-flammable surface. 

7. 

Select the battery type.

8. 

When charging is complete, disconnect the AC cord from the supply mains, remove the 

negative connector, and finally the positive connector. 

BATTERY CONNECTION INDICATOR

If the charger does not detect a properly connected battery, charging will not start and the 

digital display will show one of two messages. If the display shows 

CONNECT CLAMPS

make sure the charger is connected to the battery and the connection points are clean and 

making a good connection. If the display shows 

WARNING-CLAMPS REVERSED

, unplug 

the charger from the AC outlet, reverse the connections at the battery, and then plug the 

charger back in.

AUTOMATIC CHARGING MODE

When an Automatic Charge is performed, the charger switches to the Maintain Mode 

automatically after the battery is charged. For a battery with a starting voltage under 1 volt, 

use a manual charger to pre-charge the battery for five minutes, to get additional voltage 

into the battery.

ABORTED CHARGE

If charging cannot be completed normally, charging will abort. When charging aborts, the 

charger’s output is shut off, the green LED will flash, and the display will show 

CHARGE 

ABORTED-BAD BATTERY

. To reset after an aborted charge, unplug the charger from the 

AC outlet, wait a few moments and plug it back in.

COMPLETION OF CHARGE

Charge completion is indicated by the pulsing green LED and the digital display showing 

FULLY CHARGED-AUTO MAINTAINING

. This indicates the charger has switched to the 

Maintain Mode of operation. 

MAINTAIN MODE (FLOAT-MODE MONITORING)

When the green LED is pulsing, the charger has started Maintain Mode. In this mode, 

the charger keeps the battery fully charged by delivering a small current when necessary. 

NOTE:

 If the charger has to provide its maximum maintain current for a continuous 12 hour 

period, it will go into Abort Mode (see Aborted Charge section). This is usually caused by 

a drain on the battery, or the battery could be bad. Make sure there are no loads on the 

battery. If there are, remove them. If there are none, have the battery checked or replaced.

MAINTAINING A BATTERY

The SPI3S maintains 12 volt batteries, keeping them at full charge.

NOTE:

 The maintain mode technology allows you to safely charge and maintain a healthy 

battery for extended periods of time. However, problems with the battery, electrical 

problems in the vehicle, improper connections or other unanticipated conditions could 

cause excessive current draws. As such, occasionally monitoring your battery and the 

charging process is recommended.

13.  CALCULATING CHARGE TIME

BATTERY PERCENT AND CHARGE TIME

This charger adjusts the charging time in order to charge the battery completely, efficiently 

and safely. The microprocessor automatically performs the necessary functions. This section 

includes guidelines that can be used to estimate charging times.

 

Use the following table to 

determine the time it will take to bring a battery to full charge.

First, identify where your battery fits into the chart.

CCA = Cold Cranking Amps      Ah = Amp Hour

Find your battery’s rating on the following chart, and note the charge time given for each 

charger setting. The times given are for batteries with a 50% charge prior to recharging. 

Add more time for severely discharged batteries.

Содержание SPI3S.V2

Страница 1: ...INSTRUCTIONS FOR INTELLIGENT SPEED CHARGER BATTERY CHARGER 3AMP 12V MODEL NO SPI3S V2 SPI3S V2 Issue 4 18 17 05 19 Original Language Version Jack Sealey Limited ...

Страница 2: ...rger safely and effectively Please read understand and follow these instructions and precautions carefully as this manual contains important safety and operating instructions The safety messages used throughout this manual contain a signal word a message and an icon The signal word indicates the level of the hazard in a situation Indicates an imminently hazardous situation which if not avoided wil...

Страница 3: ...he same number size and shape as those of the plug on the charger That the extension cord is properly wired and in good electrical condition That the wire size is large enough for the AC ampere rating of the charger as specified in section 8 1 8 To reduce the risk of electric shock unplug the charger from the outlet before attempting any maintenance or cleaning Simply turning off the controls will...

Страница 4: ...contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye immediately flood the eye with cold running water for at least 10 minutes and get medical attention right away 2 10 If battery acid is accidentally swallowed drink milk the whites of eggs or water DO NOT induce vomiting Seek medical attention immediately 3 PREPARING TO CHARGE RISK OF CONTACT WITH B...

Страница 5: ...des belts pulleys and other parts that can cause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 6 4 Determine which post of the battery is grounded connected to the chassis The battery terminal not connected to the chassis has to be connected first The other connection is to be made to the chassis remote...

Страница 6: ...ed on shore To charge it onboard requires equipment specially designed for marine use 8 AC POWER CORD CONNECTIONS RISK OF ELECTRIC SHOCK OR FIRE 8 1 This battery charger is for use on a nominal 230V 50Hz circuit The plug must be plugged into an outlet that is properly installed in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet 8 2 DANGER Never alter the...

Страница 7: ...or outside of the vehicle Section 7 USING THE QUICK CONNECT CABLE CONNECTORS Connect any of the output cable assemblies to the charger in a matter of seconds Make sure to place the charger on a dry non flammable surface IMPORTANT Never connect the clip and ring terminal connectors together for use in other applications such as external battery or other power source charging or to extend the output...

Страница 8: ...itched to the Maintain Mode of operation MAINTAIN MODE FLOAT MODE MONITORING When the green LED is pulsing the charger has started Maintain Mode In this mode the charger keeps the battery fully charged by delivering a small current when necessary NOTE If the charger has to provide its maximum maintain current for a continuous 12 hour period it will go into Abort Mode see Aborted Charge section Thi...

Страница 9: ...Plugged into the AC outlet and correctly connected to a discharged battery FULLY CHARGED AUTO MAINTAINING Green LED pulsing Plugged into the AC outlet and correctly connected to a fully charged battery CHARGE ABORTED BAD BATTERY Green LED flashing Circumstances that could cause an Abort situation during charging The battery is severely sulfated or has a shorted cell and can t reach a full charge T...

Страница 10: ...l not spark if touched together No problem this is a normal condition The charger will not turn on when properly connected AC outlet is dead Poor electrical connection Check for open fuse or circuit breaker supplying AC outlet Check power cord and extension cord for loose fitting plug Green LED is lit and the display shows ANALYZING BATTERY The charger needs to check the condition of the battery T...

Страница 11: ... compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the pro...