background image

5.5.    

Check the connections of the safety thermostat and of the thermocouple: they must always be clean.

5.6.    

If necessary clean the fan blade and the inside of the heater using compressed air.

 

‰

  

WARNING: AIR CONTAMINANTS

 

Air contaminants taken into the heater will damage the unit, cause health problems and safety issues.

 

For example: Body shop filler dust and overspray dust will clog the burner diffuser, contaminate the combustion chamber and 

 

damage the internal parts of the heater. If contaminants are present the heater must be supplied with ducted clean air.

 

Please note that any parts damaged by filler dust or overspray dust will not be covered by warranty. Additionally a cleaning  

 

charge will be made for any heaters damaged by filler dust or overspray dust.

6.  TROUBlESHOOTING

fig.4

Problem

Causes

Solution

motor does not work

no electrical supply

Check terminal board with a 
tester

motor works but the burner 
does not light up and after a 
few seconds the heater stops

The gas cylinder tap is closed

open the gas tap

The gas cylinder is empty

U

se a new cylinder

The nozzle is obstructed

Remove the nozzle and clean 
it

The solenoid gas valve is not 
open

Check that the solenoid valve 
works

There is no spark

Check the position of the 
electrode

The burner lights up but after a 
few seconds the heater stops

defective connection between 
censor and safety device

Check and connect properly

defective safety device

Replace the safety device

The heater stops during 
operation

I

nsufficient air flow

Check that the motor works 
properly

I

nsufficient gas supply due to 

ice formation on the cylinder

Check and use a larger 
cylinder or two cylinders 
connected together

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENvIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: no liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGUlATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 

waste authority for recycling information.

l

P100.V6     Issue: 1   22/07/19

Original Language Version

© Jack Sealey limited

Содержание SPACE WARMER LP100.V6

Страница 1: ...n a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING failure to comply with ...

Страница 2: ...as type Propane Output 61 000 102 000Btu hr 18 30kW Gas consumption 1 3 2 18kg hr Airflow 580cfm 4 operation 4 1 Refer to instructions in Safety section 1 above 4 2 Safety clearance see fig 2 4 3 Connect gas supply hose to pressure regulator and connect regulator to a suitable LPG cylinder left hand threaded nut 4 3 1 Open the gas cylinder tap and check supply hose and fittings for gas leaks Use a...

Страница 3: ...t properly defective safety device Replace the safety device The heater stops during operation Insufficient air flow check that the motor works properly Insufficient gas supply due to ice formation on the cylinder Check and use a larger cylinder or two cylinders connected together Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR 01284 757500 01284 703534 sales sealey...

Страница 4: ... control Yes No plus week timer Other control options multiple selections possible Room temperature control with presence Yes No detection Room temperature control with open Yes No window detection With distance control option Yes No With adaptive start control Yes No With working time limitation Yes No With black bulb sensor Yes No Information requirements for gaseous liquid fuel local space heat...

Отзывы: