background image

5.  DescriPtion of cHarGinG PHases

 6.   Maintenance

6.1

  This charger requires no specific maintenance other  

 

 

than cleaning which should be done with a dry cloth or a   

 tissue. 

Do not

 use any solvents or cleaning agents on   

 

the casing.

6.2

  Ensure that the charger is unplugged from the mains    

 

before installing or performing any maintenance.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPortant: 

No liability is accepted for incorrect use of this product. 

Warranty: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inforMation:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole uK Distributor, sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SMC03.V2    Issue: 1 - 31/10/13

 

©

 

Jack Sealey Limited 

4.5 

MoDe 3 DescriPtion (*14.7/4.0a)

4.5.1 This mode is mainly for charging large batteries with  

 

a capacity over 14Ah in cold conditions or for charging  

 

several AGM batteries with a capacity over 20Ah.  

 

Press the MODE button until the LED adjacent to the  

 

ice crystal symbol is illuminated. Charging will 

 

automatically start with a set delay with a current of  

 

3.8A   ± 10% and the ‘charging’ LED will illuminate. This  

 

LED will remain on throughout the entire charging  

 

process until the battery is fully charged up to *14.7V

 

± 0.25V. At this stage the ‘charging’ LED will extinguish  

 

and the ‘fully charged’ LED will illuminate. The trickle  

 

charge current now becomes available for battery  

 maintenance. 

 

4.6 

MoDe 4 DescriPtion (7.5/4a) 

4.6.1 This mode is mainly for charging all types of 6 volt  

 

batteries with a capacity over 14Ah. Press the MODE  

 

button until the LED adjacent to the 6V battery symbol  

 

is illuminated. Charging will automatically start with a set  

 

delay and the ‘charging’ LED will illuminate. This LED  

 

will remain on throughout the entire charging process  

 

until the battery is fully charged up to 7.5V ± 0.25V.  

 

At this stage the ‘charging’ LED will extinguish and the  

 

‘fully charged’ LED will illumniate. The trickle charge

 

current now becomes available for battery 

 maintenance.

4.7 

MoDe 5 DescriPtion (cal)

4.7.1  This mode is for lead calcium or a battery below *10.5 

 

volts with no capacity to absorb charging current, the  

 

charger will automatically raise the output up to *17  

 

volts. The Mode 5 LED will illuminate and flash, the  

 

‘charging’ LED will illuminate. If the battery cannot be  

 

recovered within 2 hours the “Fault” 

(!)

 LED will 

 

illuminate. The battery may require replacing.

4.8 

fauLt Protection

4.8.1  In the case of a short circuit, open circuit, reversed 

 

polarity or battery voltage below *7.5V ± 0.5, the

 

charger will turn off the electronic system and revert  

 

to standby mode. Additionally the “Fault” 

(!)

 LED will

 

illuminate. The fault must be identified and resolved  

 

before any of the charging modes are initiated.

4.9 

oVerHeatinG Protection

4.9.1  If the charger becomes too hot during the charging  

 

process or due to extreme ambient temperatures the  

 

power output is automatically reduced to a trickle  

 

charge to protect the unit. Once the temperature drops  

 

the charger will increase the power output automatically.

5.1

 The 

sMc03.V2

 charger has a nine step fully automatic  

 

charging cycle as shown in Fig.3 above, which is 

 

indicative of the typical charging curve for a battery.

5.2  PHase 1 through 5 DiaGnosis & recoVery:

 As  

 

soon as one of the charging modes is selected the 

 

diagnostic function automatically detects the condition  

 

of the battery i.e. voltage. If the voltage of a deeply 

 

discharged battery is over *7.5V ± 0.5V the charger  

 

begins to pulse charge with a small current to recover  

 

it. Pulse charging ceases when the voltage reaches  

 

*10.5V ± 0.5V. If the voltage detected is over *10.5V  

 

± 0.5V the charger skips pulse charging and switches to

 

the preselected charging mode.

5.3  PHase 6 BuLK:

 Up to 80% of the charge is delivered  

 

in this phase.

5.4  PHase 7 aBsorPtion:

 A constant low charging 

 

current raises the voltage from *14.1V to 14.4V over a  

 

period of time without gassing the  battery. In this phase  

 

complete charging up to almost 100% is achieved.  

 

When full charge is reached the charger switches to  

 

phase 8 and 9.

5.5  PHase 8 & 9 Maintenance cHarGe:

 If the battery  

 

is loaded and/or the voltage across the terminals drops  

 

below *12.8V, the charger starts a maintenance charging  

 

pulse at a constant 0.8A until the voltage  reaches *14.4V   

 

at which point  the maintenance charge is turned off. The  

 

charger  continues to monitor the battery condition and  

 

will cycle between trickle charge and maintenance  

 

charge  indefinitely to keep the battery in peak condition.  

 

The charger can be left connected to the battery in order  

 

to perform this maintenance function.

 

note!

 

Figures marked thus * are for 12 volt batteries and 

 

all figures are offered as a guide only. The charger is 

 

automatic  and requires no measurements by the user.

environmental Protection.

  

Recycle unwanted materials instead of disposing of them as  

 

  waste. All tools, accessories and packaging should be sorted,  

 

  taken to a recycle centre and disposed of in a manner which is 

 

  compatible with the environment.

 

 

  When the product is no longer required, it must be disposed of  

 

  in an environmentally protective way.

 

 

Fig.3

Содержание SMC03.V2

Страница 1: ...y a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N d After wiring check that there are no bare wires all wires have been correctly connected the cable outer insulation extends beyond the cable restraint and that the restraint is tight Double insulated products which are alway...

Страница 2: ...ccessory plug and hard wired terminals incorporating a water tight plug and socket for permanent installation For motorcycles and cars 3 connection to battery Original Language Version SMC03 V2 Issue 1 31 10 13 Jack Sealey Limited NOTE THE CHARGER SHOULD BE CONNECTED TO THE BATTERY OR THE VEHICLE ACCESSORY SOCKET BEFORE CONNECTING TO THE MAINS SUPPLY 3 1 The output cable from the charger terminate...

Страница 3: ...n in that mode However once the battery is fully charged and if the charger remains connected the charger will switch to trickle charge mode and will remain in this mode even if the user selects another mode This protects the battery from being damaged 4 3 MODE 1 DESCRiption 14 4v 1 0a 4 3 1 This mode is suitable for charging small batteries with a capacity below 20Ah Press the MODE button until t...

Страница 4: ...If the battery cannot be recovered within 2 hours the Fault LED will illuminate The battery may require replacing 4 8 FAULT PROTECTION 4 8 1 In the case of a short circuit open circuit reversed polarity or battery voltage below 7 5V 0 5 the charger will turn off the electronic system and revert to standby mode Additionally the Fault LED will illuminate The fault must be identified and resolved bef...

Отзывы: