background image

  

DANGER! The use of damaged blades is dangerous and may cause injury.

  

WARNING! Ensure that the cut-off saw is unplugged from the power supply before attempting to change the cutting disc.

5.1 IMPORTANT! 

Cutting discs used with this machine shall be of an adequate speed rating and suitable for the task in hand.

 

Order from your dealer quoting model no. PTC/355C.  

5.1.1  Before using a cutting disc ensure that there are no fissures or cracks in it. Once mounted on the cut-off machine, test the disc before  

 

use by facing the cut-off saw in a safe direction (turned away from yourself, others and vulnerable items) and run it for a short time. 

5.2. 

REMOVING AND INSTALLING CUTTING DISCS (Refer to figs. 5 & 6)

NOTE: 

Removing and installing discs is only to be undertaken by competant persons.

5.2.1  Lift the arm into the up position. 

5.2.2  Loosen the two hex screws to allow the disc access cover to be moved to the right and removed.

5.2.3  Pull the blade catch down and to the right and turn the blade using a 8mm hex key until the catch engages and prevents the blade from turning.

5.2.4  Keep the disc catch engaged and undo the disc hex screw anticlockwise.

5.2.5  Push back the disc guard and undo the hex screw to remove the disc, take care to note the orientation and position of the flanges and  

 

 

washers. Fit the new disc, assembly is the reverse of the above instructions. 

 

NOTE: 

Take care to not overtighten the disc hex screw.

 

WARNING! Ensure that the cut-off saw is unplugged from the power supply before attempting any maintenance.

6.1

 

Regularly clean the dust which accumulates inside the protective guard and on the external parts.

6.2

 

Periodically clean and oil the vice screw.

6.3

 

Change the cutting blade when it is worn and/or does not operate efficiently.

6.4

 

Before each use, check for obvious signs of damage to the saw. Also check for loose screws and other moving parts, incorrectly  

 

 

mounted or misaligned parts and any other factors that might create an unsafe working environment.  

 

WARNING! 

Should excessive noise or vibration occur, cease use immediately. Turn off saw and disconnect from power supply.

 DO

    

 

NOT

 use the saw again until the problem has been fully resolved.

6.5. 

CHANGING THE MOTOR BRUSHES.

6.5.1.  The motor brushes should be checked periodically for wear and renewed when worn down or pitted. 

6.5.2.  Isolate from the power supply.

6.5.3.  Unscrew the plastic covers and withdraw the brush assemblies for inspection.

6.5.4.  The brushes can be accessed either side of the motor casing, see fig.7. Insert the new brush into the keyway. Place the plastic cap over  

 

the head of the brush assembly and press the spring downwards ensuring that the tabs on either side of the brush head enter the same  

 

keyway as the brush. Screw the caps back into position. 

 

Fig.5

Fig.6

Fig.7

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to 

www.sealey.co.uk, email [email protected] or phone 01284 757500.

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

 

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, 

taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations

Dispose of this product at the end of its working life in compliance with the EU Directive on 

Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed

of in an environmentally protective way. Contact your local solid waste authority for recycling information.

SM355D110V    Issue: 1   09/10/14     

Original Language Version

© Jack Sealey Limited

 5.  DISC CHANGE

 6.  MAINTENANCE

Содержание SM355D110V

Страница 1: ...9 requires that all portable electrical appliances if used on business premises are tested by a qualified electrician using a Portable Appliance Tester PAT at least once a year 1 1 2 The Health Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators If in any doubt about electrical safety contact...

Страница 2: ...t or use in damp or wet locations or areas where there is condensation WARNING DO NOT use the cut off saw where there are flammable liquids solids or gases such as paint solvents and including waste wiping rags etc DO NOT operate the cut off saw if any parts are missing or damaged as this may cause failure and or personal injury DO NOT remove the safety guard whilst the cut off saw is in use DO NO...

Страница 3: ...functions correctly 4 4 MITRE CUTTING 4 4 1 To cut at an angle loosen the vice backstop locking screw by turning it anticlockwise Align to the desired angle using the graduated scale on the base plate shown in fig 4 and retighten the vice backstop screw Place the workpiece against the backstop and move the other jaw up to it and securely tighten 4 5 ON OFF SWITCH 4 5 1 The On Off switch is locked ...

Страница 4: ...n until the problem has been fully resolved 6 5 CHANGING THE MOTOR BRUSHES 6 5 1 The motor brushes should be checked periodically for wear and renewed when worn down or pitted 6 5 2 Isolate from the power supply 6 5 3 Unscrew the plastic covers and withdraw the brush assemblies for inspection 6 5 4 The brushes can be accessed either side of the motor casing see fig 7 Insert the new brush into the ...

Отзывы: