6.  CONSUMAbLES

 

‰

   WARnInG! do noT USe dISCS THAT ARe dAmAGed, oR SUSPeCTed To Be dAmAGed.

6.1.    

Before using a grinding/cutting disc ensure that there are no fissures or cracks. once mounted on the grinder, test the disc before use by  

 

facing the grinder in a safe direction (point away from yourself, others and vulnerable items) and run for a short time. 

 

   dAnGeR! Use of damaged discs is dangerous and may cause personal injury.

6.2.    

Grinding and cutting discs used in association with this machine shall be of an adequate speed rating and be suitable for the job in hand.  

 

The discs shall be made in accordance with British Standard 4481:Part 1 1989. only persons holding a grinding wheel certificate are  

 

authorised to change grinding discs. ensure that the speed rating on the disc is equal to, or higher than, that of the grinder.

7.  MAINTENANCE

 

‰

  

WARNING! 

ensure that the grinder is disconnected from the mains power supply before attempting any maintenance.

7.1.    

Cleaning

7.1.1.   

Keep the grinder ventilation slots clean and free from obstructions. If available, blow compressed air into the vents to clear any internal  

 

dust (safety goggles must be worn when undertaking this process). Keep the outer case of the grinder clean and free from grease. 

 

8

  

DO NOT

 wash with water or use solvents or abrasives.

7.2.    

Changing the motor brushes (SG101.V2, SG115.V2)

7.2.1.   

Remove the screw at the rear of the grinder then pull the rear body casing away. 

7.2.2.   

Release the brush assembly cap as in fig.9.

7.2.3.   

Remove the brush assembly and replace. 

7.2.4.   

Refitting is a reversal of the above procedure.

7.2.5.   

Repeat for the second brush on the other side of the grinder.

7.3.    

Changing the motor brushes (SG125, SG2303.V2)

7.3.1.   

Remove the screw from the side panel half way up the grinder, then remove panel

7.3.2.   

Release the tension spring from the carbon brush and slide it out of the brush holder. (fig.10)

7.3.3.   

Replace the motor brush.

7.3.4.   

Refitting is a reversal of the above procedure.

7.3.5.   

Repeat for the second brush on the other side of the grinder.

   fig.6

   fig.7

   fig.8A

   fig.8C

   fig.8B

SG101.V2, SG115.V2, SG125, SG2303.V2 Issue 5 (1,3) 02/05/18

Original Language Version

© Jack Sealey limited

Содержание SG101.V2

Страница 1: ...s plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician When a BS 1363 A UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plug according to the following instructions UK only a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect th...

Страница 2: ... modified accordingly Personal protective equipment We are not aware of any personal protective equipment PPE that provides protection against vibration injury that may result from the uncontrolled use of this tool We recommend a sufficient supply of clothing including gloves to enable the operator to remain warm and dry and maintain good blood circulation in fingers etc Please note that the most ...

Страница 3: ...embly SG2303 V2 4 3 1 The guard may be orientated at any angle to suit the grinding task required and should be positioned to allow maximum working performance whilst providing maximum personal protection for the operator 4 3 2 Take the guard fig 1 item 2 and unlock the clamp On the inside of the guard clamping collar is a small pip indicated by arrow A in fig 5 which must be aligned with a notch ...

Страница 4: ...he switch forward and pressing down I 5 2 3 To turn off the machine press the switch at the rear and it will spring back to the OFF position O 5 3 ON OFF Switch SG125 SG2303 V2 5 3 1 Once plugged into the mains power supply the grinder is started by a two stage switching operation Place your fingers over the switch and using your index finger unlock the trigger by pushing the lock lever forwards a...

Страница 5: ...er ventilation slots clean and free from obstructions If available blow compressed air into the vents to clear any internal dust safety goggles must be worn when undertaking this process Keep the outer case of the grinder clean and free from grease 8 8 DO NOT wash with water or use solvents or abrasives 7 2 Changing the motor brushes SG101 V2 SG115 V2 7 2 1 Remove the screw at the rear of the grin...

Страница 6: ...of the product and fluids according to local regulations Weee Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our poli...

Отзывы: