eNVirONmeNt PrOteCtiON

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

important

: no liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Weee reGulAtiONS

dispose of this product at the end of its working life in compliance with the eU directive on Waste electrical and electronic equipment 
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

Symptom

Potential cause

Possible remedy

Unit does not operate

Is power supply connected?

Insert the plug into an electrical outlet fully and 

securely - check fuse in plug is oK.

Check to see if the water tank is full of water 

i.e. is water level warning light on See 4.5.1.1.

Remove front cover 4.5.1.2.

empty water out of the tank. See 4.5.1.4.

Check to see if the water tank is fitted properly 

in position.

Remove front cover 4.5.1.2. and reposition 

tank.

d

ehumidified volume 

is small

I

s filter dirty / clogged ?

C

lean filter section 5.1.

Check for any obstructions to front and back 

air inlets / outlets of unit.

See section 1.2.

low ambient temp.

Unit does not work below approx 5

o

C.

low ambient humidity.

Unit has reached required level set.

Humidity remains too 

high.

Room size may be too large.

Room size may exceed 12m

3

.

doors and windows may be opened and 

closed frequently.

Keep doors and windows shut during 

operation.

The dehumidifier is used together with a 

kerosene heater which emits water vapour.

Turn heater off.

7.  trOuBleShOOtiNG

  

Содержание SDH102

Страница 1: ...alified electrician When a BS1363 A UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plug according to the following instructions UK only a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N d After wiring check that there are no...

Страница 2: ...ty is 5 greater than set value the unit will start If the room humidity is 5 less than the set value the unit will stop The Display fig 1 7 will display the current humidity level when running Options selected will be highlighted If Mode is set to Continuous the fan defaults to high speed and cannot be changed 4 1 2 INSIDE DRYING prior to long term storage 4 1 2 1 Turn machine on fig 1 5 Press Ins...

Страница 3: ...sons authorized by an accredited agency certifying their competence to handle refrigerants in compliance with sector legislation should work on refrigerant circuit 9 9 All repairs must be carried out in accordance with the manufacturer s recommendations 9 9 Maintenance and repairs requiring the assistance of other qualified personnel must be carried out under the supervision of specialists in the ...

Страница 4: ...anufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak 5 1 14 Cabling 5 1 14 1 Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans 5 1 15 Detectio...

Страница 5: ...s in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs 5 1 21 1 The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including when applicable flammable refrigerants In addition a set of calibrated weighing...

Страница 6: ...ith the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Symptom Potential cause Possible remedy Unit does not operate Is power supply connected Insert the plug into an electrical outlet fully and securely check fuse in ...

Отзывы: