Original Language Version
© Jack Sealey limited
8. errOr cOdes
9. trOUbleshOOting
errOr
descriptiOn
cAUse
cOde
F01
The battery voltage is still under 10V (for a 12V battery)
Could be caused by trying to charge a 6 volt battery on the
or 5V (for a 6V battery) after 2 hours of charging.
12V setting, or the battery could be defective; have it checked
or
replaced.
F02
The charger cannot desulphate the battery.
The battery could not be desulphated; have it checked or
replaced.
F03
The battery was unable to reach the "full charged"
Could be caused by trying to charge a large battery or bank
voltage.
of batteries on too low of a current setting, or the battery may
have shorted cell. Try again with a higher current setting, or
get
the
battery
checked
or
replaced.
F04
The connections to the battery are reversed.
The battery is connected backwards. Unplug the charger and
reverse
the
connections
to
the
battery.
F05
The battery was unable to keep the battery fully
The battery won't hold a charge. Could be caused by a drain
charged in maintain mode.
on the battery, or the battery could be defective. make sure
there are no loads on the battery. If there are, remove them. If
there are none, have the battery checked or replaced.
F06
The charger detected that the battery may be getting too
The charger automatically shuts the current off if it detects
hot (thermal runaway).
the battery may be getting too hot or the battery may have
a shorted cell. Have the battery checked or replaced.
If you get an error code, check the connections and settings and/or replace the battery.
prOblem
pOssible
cAUse
sOlUtiOn
ConneCTed led is The battery is not connected correctly.
Check for correct connection to the battery.
not on.
Battery voltage is at zero volts.
Turn off everything in the car and try to connect again.
Input fuse is blown.
Replace the fuse (5 Amp fuse).
output breaker has tripped.
Push button to reset the breaker.
CHARGING LED is
Charger is in Abort Mode
Unplug the charger from the mains supply and plug it
flashing.
back in.
Battery is sulphated.
Use
(Desulphation Mode) for 8 hours.
Battery is defective.
Have the battery checked.
FULL CHARGE LED Surface charge voltage is high.
Replace the battery.
is on, but battery is not
fully charged.
Battery voltage is very low
Unplug the charger from the mains supply and plug it
and the charger detects it as
back in.
6V not 12V.
All LEDs are lit in an
A button may have been pressed while the
Unplug the charger from the mains supply and plug it
erratic manner.
charger was being plugged in.
back in, without touching the control board.
sealey group, Kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7Ar
01284 757500
01284 703534
www.sealey.co.uk
note
: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important
: no liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
enVirOnment prOtectiOn
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Weee regUlAtiOns
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
S
CI90S.V2 | Issue:2 (1) 15/11/19