instructions for
ELECTRONIC COMBINATION
FIREPROOF SAFES
model no’s:
SCFS01.V2, SCFS03.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING!
these safes are heavy and care should be exercised in transit and handling to ensure that no one is injured.
WARNING!
Due to the fireproof concrete infill material both safes are a 2 man lift both for transit and installation.
8
8
88
DO NOT
install in areas where damp and condensation are present.
2. INTRODuCTION
H
eavy duty multi-walled fireproof safes injected with fireproof foaming concrete offering up to one hour fire resistance with UL approval. Finished
with a corrosion resistant powder coating. Double safety lock requires both electronic access code and key to open the locking mechanism. Also
includes one removable shelf. (SCFS03 one tray). Batteries included.
3. SPECIFICATION
model no: ............................................................
SCFS01.V2
e
xternal dimensions (W x D x H):
...........
400 x 330 x 330mm
i
nternal dimensions (W x D x H):
.............
315 x 230 x 220mm
t
hickness wall/door:
................................................
40/75mm
s
helf quantity:
......................................................................
1
4. INSTALLATION
4.1.
Careful consideration should be given to the location of the safe to ensure that it is discreetly placed and not easily found by any
intruders.
4.2.
Appoint key holders for the two keys provided and discuss security arrangements for the safekeeping and availability of the keys.
5. OPERATION
p
5.1.
Refer to fig.2 for function and position of the two sets of keys.
5.2.
First time opening of safe
5.2.1.
Fit batteries. Use keys to open door to insert batteries into the
compartment on the back of the door, see fig.1.
5.3.
Factory code setting:
Personal code “1234” and Master code
“123456”.
5.4.
Personal code setting:
5.4.1.
Option 1:
Press RESET button once, the display shows “------” which
means that you can set a personal code.
Input a 1-8 digital code and press “#” to confirm, the display
shows “IN” which means that the Personal Code set has
been successful.
5.4.2.
Option 2:
Open the door with the personal code. When the display
shows “OPEN” and the LCD back light is blue,
press “*” key, the system is in ‘changing personal mode state’
and shows “------”.
Now input a new 1-8 digit personal code. Press “#” to confirm.
5.5.
Master code setting:
5.5.1.
Option 1:
Press “#” key and the display will illuminate and show “------”.
Press “0” twice and press the RESET button, the display will
show “------” which means that the Master code can be set.
Input a 1-8 digit code, then press “#” to confirm, the display
shows “IN” which means the Master code has been successful.
s
CFS01.V2, SCFS03.V2 | Issue:2(5) 01/03/18
Original Language Version
© Jack Sealey Limited
refer to
instruction
manual
model no: ............................................................
SCFS03.V2
e
xternal dimensions (W x D x H):
...........
355 x 390 x 515mm
i
nternal dimensions (W x D x H):
.............
255 x 245 x 310mm
t
hickness wall/door:
................................................
55/80mm
t
ray quantity:
.......................................................................
1
Fig.1
Fig.2