background image

INSTRUCTIONS FOR:

COMPRESSORS 270ltr VERTICAL BELT 

DRIVE 5.5 / 7.5 / 3PH 2-STAGE WITH CAST

CYLINDERS

MODEL No: 

SACV42755B,SACV52775B

  1.  SAFETY

1.1  

ELECTRICAL SAFETY 

 

  

WARNING! 

ELECTRICAL INSTALLATION OF COMPRESSOR TO A 3-PHASE 415VOLT SUPPLY MUST ONLY BE   

 

CARRIED OUT BY A QUALIFIED ELECTRICIAN. 

 

Make sure the power supply cable is correctly connected to the earth. It is the user’s responsibility to read, understand and  

 

comply with the following: 

 

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,    

 

plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is  minimised by the installation of  

 

appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board.  

 

You must

 also read and understand the following instructions concerning electrical safety. 

1.1.1. The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by a qualified   

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance and  

 

the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure insulation on all cables and the product itself is safe before connecting to mains power supply. 

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, especially power connections, to    

 

ensure that none are loose. 

1.1.6. 

Important:

 

Ensure the voltage marked on the product is the same as the electrical power supply to be used. A three phase plug must  

 

be fitted to this machine.

1.1.7. 

DO NOT

 pull the powered appliance by the power cable. 

1.1.8. 

DO NOT

 pull power plugs from sockets by the power cable.

1.1.9. 

DO NOT

 use worn or damage leads, plugs or connections. Replace immediately or have repaired by a qualified electrician. 

                                                                                

 

                                                                                

GUIDE TO SYMBOLS

Original Language Version

 © Jack Sealey Limited

SACV42755B,ASACV45775B   Issue: 1 - 17/12/14

SACV42755B

SACV42775B

Warning: 

Electricity

Warning: 

Hot Surface

Warning:  

Automatic start-up

Wear ear protection

Read the instruction manual before use

DO NOT

 open the air cock before an air hose is attached

DO NOT

 operate the compressor with enclosure

displaced

Ensure oil level is 

correct before first use

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions and properly maintained, give you years of trouble free performance.

Содержание SACV52775B

Страница 1: ...lf is safe before connecting to mains power supply 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply leads plugs and all electrical connections for wear and damage especially power connections to ensure that none are loose 1 1 6 Important Ensure the voltage marked on the product is the same as the electrical power supply to be use...

Страница 2: ...ylinder head or pipe from head to tank as these may be hot and will remain so for some time after shutdown 7 DO NOT attempt to move the compressor by pulling the air tool hose 7 DO NOT use this product to perform a task for which it has not been designed 7 DO NOT operate the compressor with the belt guard removed 7 DO NOT deface the certification plate attached to the end of the compressor tank 7 ...

Страница 3: ...he plug out as the pressure relief will not then operate and motor damage may result upon restart When the compressor runs correctly and is stopped correctly there will be a a whistle of compressed air when the motor stops b a protracted whistle about 20 25 seconds when the compressor starts with no pressure in the tank 5 OPERATION fig 2 fig 1 a 4 1 Remove compressor from packaging and inspect for...

Страница 4: ...4 OPERATIONS TO BE CARRIED OUT EVERY 100 HOURS a Check the automatic cut out at max pressure and the automatic cut in at 2bar below 6 MAINTENANCE 6 5 OPERATIONS TO BE CARRIED OUT EVERY 400 HOURS a Replace the lubricating oil For oil specifications see 6 6 Remove the dipstick breather plug then unscrew oil drain plug fig 1 fig 5 draining the oil into a container Drain when the compressor is hot so ...

Страница 5: ...ranty NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of this product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim 01284 757500 01284 703534 sales sealey co uk Sole UK Distributor Sealey...

Страница 6: ......

Страница 7: ...2 EC Machinery Directive 2005 88 EC Outdoor Noise Emissions Directive 2006 95 EC Low Voltage Directive 2012 19 EU WEEE Directive 2004 108 EC EMC Directive 2011 65 EU RoHS Directive 2009 142 EC Gas Appliances Directive 97 23 EC Pressure Equipment Directive And the following harmonised standard s Technical file compiled by Jack Sealey Ltd Signed Date Place Bury St Edmunds Name Position Being the res...

Страница 8: ...2 EC Machinery Directive 2005 88 EC Outdoor Noise Emissions Directive 2006 95 EC Low Voltage Directive 2012 19 EU WEEE Directive 2004 108 EC EMC Directive 2011 65 EU RoHS Directive 2009 142 EC Gas Appliances Directive 97 23 EC Pressure Equipment Directive And the following harmonised standard s Technical file compiled by Jack Sealey Ltd Signed Date Place Bury St Edmunds Name Position Being the res...

Отзывы: