Sealey SAC9030VE Скачать руководство пользователя страница 2

4.  OPERAtiON  

V-twin pump with aluminium cylinders for reduced weight and cast 

iron liners for improved resistance to wear. suitable for general 

purpose workshop applications. Pump directly coupled to heavy-duty 

induction motor for reliable operation. Precision welded receiver tank 

manufactured to meet Pressure Vessel directive 2009/105/ec. fitted 

with fully automatic pressure cut-out switch, air regulator and 

pressure gauges for tank and supply. supplied with handle and 

wheels for easy manoeuvrability. fitted with AstA/Bs approved 

non-rewirable plug. 

3. PREPARAtiON

3.1.

 

remove compressor from packaging and inspect for any  

 

shortages or damage. If anything is found to be missing or  

 

damaged contact your supplier.

3.2.

 

save the packing material for future transportation of the  

 

compressor. We recommend that you store the packing in a  

 

safe location, at least for the period of the guarantee. then, if  

 

necessary, it will be easier to send the compressor to the  

 

service centre.

3.3.

 

confirm that the mains voltage corresponds with the voltage  

 

shown on the compressor data plate.

3.4.

 

Assemble the wheels (fig.A.X) and rubber feet (fig.A.Y) to  

 

the main frame using the nuts, bolts and washers supplied.

3.5.

 

the compressor should be operated on a flat level surface,  

 

or one that does not exceed 5° either transversely or  

 

longitudinally (fig.1), and should be in a position that allows  

 

good air circulation around the unit.

3.6.

 

remove the plastic transit plug from the oil filler hole.

3.7.

 

Before using the compressor check the oil level by referring  

 

to the oil sight glass (fig.2c). If the oil level is not up to the  

 

red centre mark it should be further topped up with    

 

recommended oil (see section 5.7). screw the filler/breather  

 

cap into the aperture as shown in fig.2B. 

3.8.

 

screw the back half of a filter unit into the downward facing  

 

port openings in each head as shown in fig.2.A. Place a filter  

 

cover over each threaded rod protruding from the back half  

 

of the filter and secure each with a wing nut. refer also to  

 fig.4.

fig.2

  

WARNiNG! Ensure that you have read, understood and  

 

apply Section 1 safety instructions.

4.1.   iMPORtANt.  the use of extension leads to connect this  

 

compressor to the mains is not recommended as the  

 

resulting voltage drop reduces motor, and therefore  

  

pump, performance and could damage your compressor.

4.2.   take care when selecting tools for use with the    

 

compressor. Air tool manufacturers normally express the   

 

volume of air required to operate a tool in cubic feet per  

 

minute (cfm). 

fig.A

2.  iNtROdUCtiON & SPECiFiCAtiON

3   

Keep children and unauthorised persons away from the  

   

working area.

7   

dO NOt

 disassemble compressor for any reason. the unit  

   

must be checked by qualified personnel only.

7   

dO NOt

 use the compressor outdoors, or in damp, or wet,  

   locations.

7

  

dO NOt

 operate within the vicinity of flammable liquids,  

   

gases or solids.

7   

dO NOt

 touch compressor cylinder, cylinder head or pipe  

   

from head to tank as these may be hot.

7   

dO NOt

 use this product to perform a task for which it has  

   

not been designed.

7   

dO NOt

 deface the certification plate attached to the  

   

compressor tank.

7  

dO NOt

 cover the compressor or restrict air flow around the  

 

unit whilst operating.

q  

dANGER! dO NOt

 direct the output jet of air towards  

 

people or animals.

7

 

dO NOt

 operate the compressor without an air filter.

7

 

dO NOt

 allow anyone to operate the compressor unless  

 

they have received full instructions.

  

WARNiNG! 

the air tank is a pressure vessel and the  

 

following safety measures apply:

7

 

dO NOt

 tamper with the safety valve, 

dO NOt

 modify or  

 

alter the tank in any way and 

dO NOt

 strap anything to the  

 tank.

7

 

dO NOt

 subject the tank to impact, vibration or to heat and  

 

dO NOt

 allow contact with abrasives or corrosives.

3

 

drain condensation from tank daily. 

  

WARNiNG!

 If an electrical fuse blows, ensure it is  

 

replaced with an identical fuse type and rating. 

 

3

 

When not in use, store the compressor carefully in a safe,  

 

dry, childproof location.

MOdEL:

 ..........................................................................

SAC9030vE

motor output: ..................................................................................3hp

Voltage/phase: ....................................................................230V - 1ph

rated supply: .................................................................................13A

noise power: ...........................................................................95dB(A)

Air displacement: .................................................. 11.96cfm-338.71l/m

maximum free air delivery: ...................................7.76cfm-219.76l/mV

tank capacity: ................................................................................90ltr

max pressure: .................................................................... 116psi/8bar

Weight:... ......................................................................................54kg

dimensions (W x d x H): ......................................950 x 420 x 720mm

fig.1

sAc9030Ve     Issue no: 3 - 18/06/13

Original Language Version

© Jack sealey limited 2013

"X"

"Y"

1000

Wall

Содержание SAC9030VE

Страница 1: ...f electric shock is minimised by the installation of appropriate safety devices A Residual Current Circuit Breaker RCCB should be incorporated in the main distribution board We also recommend that a Residual Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualifie...

Страница 2: ... understood and apply Section 1 safety instructions 4 1 IMPORTANT The use of extension leads to connect this compressor to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performance and could damage your compressor 4 2 Take care when selecting tools for use with the compressor Air tool manufacturers normally express the volume of air required to operate...

Страница 3: ...t pressure in the tank rises and that the compressor stops automatically when the maximum pressure is reached written on the specification plate and shown on the gauge fig 3 6 The compressor will now operate automatically The pressure switch fig 3 8 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls below the minimum threshold approximately 2 bar 29psi le...

Страница 4: ...air tank Referring to fig 6 and fig 8 remove the non return valve cap 3 spring 2 and seal 1 Clean the seal and its seat or if necessary replace the seal 3 Air leaks from tank body or tank welds Internal corrosion caused by infrequent tank draining or non permitted modifications to tank Tank could rupture or explode Cannot be repaired DISCONTINUE USE IMMEDIATELY 4A Motor stops and will not restart ...

Отзывы: