background image

7.2.2. 

  

If the filter frame and filter mesh are clogged with dust, the function of the air-conditioner may decrease.

7.2.3. 

  

Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow (as shown in fig 9).

7.2.4. 

  

Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow (as shown in fig 8).

7.2.5. 

  

Remove the filter frame first and then take out the filter mesh.

 

NOTE:

 when taking out the filter frame or filter mesh, the force shall be applied evenly to avoid twisting or damage of the filter frame or  

 

filter mesh.

7.2.6.   

Place the evaporator filter frame, condenser filter frame, evaporator filter mesh, and condenser filter mesh into warm water (about  

 

40°C). Use neutral cleaner. Dry in the shade. (Fig 10)

 

NOTE:

 

DO NOT

 damage the mesh fabric on the filter frame and filter mesh.

7.3. 

 

 

INSTALLATION OF THE FILTER FRAME AND FILTER MESH 

(fig.8, 9, 10)

7.3.1. 

  

Install the filter mesh first and then install the filter frame.

7.3.2. 

  

To install the evaporator filter mesh and condenser filter mesh, point the back end of the filter mesh toward the socket and then push  

 

the filter mesh evenly and gently into the socket.

 

NOTE:

 Install the filter mesh in the reverse order of removal. The filter mesh must be installed into place; otherwise, the filter frame  

 

may not be installed into place.

7.4. 

  

CLEANING OF THE HANDLE POSITION AND REMOTE CONTROL STORAGE AREA

7.4.1. 

  

Remove the remote control from its storage place in the handle (fig.11). 

7.4.2.   

Clean the handle position and remote control storage area with damp soft cloth only. 

DO NOT

 allow water to drip into the unit. 

DO

  

 

NOT

 soak the cleaning cloth.

8.  MOVING THE UNIT

8.1. 

  

To move the unit, hold the top of the air outlet on the front of the unit with one hand and the handle position at the top of the back of  

 

the unit with another hand. Ensure that the unit remains upright. 

DO NOT

 hold the horizontal louvre by hand.

8.2. 

  

Leave the unit in the upright position when handling or moving it.

8.3. 

  

To handle or move the unit, drain the water in the unit first to prevent the water in the unit from flowing onto the ground or carpet.

8.4. 

  

If the remote control is currently stored in the handle recess, remove it temporarily (fig.11).

9.  STORAGE

9.1. 

  

Unscrew the drain cap, unplug the water plug and drain the water in the water tray to a suitable vessel.

 

NOTE:

 

DO NOT

 tilt the unit any further than 30° from vertical.

9.2. 

  

Start the unit, adjust mode to the low fan speed setting, keep the unit in this state for half a day in order to dry the interior of the unit to  

 

prevent mould.

9.3. 

  

Turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, insert the plug into the storage point on the  

 

rear of the unit; install the water plug and drain cap.

9.4. 

  

Remove the exhaust hose assembly and store appropriately to prevent damage.

 

NOTE:

 to remove the exhaust hose assembly, hold the handle of the exhaust hose retaining clamp, pull the retaining clamp outward

 

evenly, rotate the retaining clamp clockwise to open. Remove the exhaust hose assembly.

9.5. 

  

Pack the air-conditioner in a soft plastic bag. Store the unit in a dry and dust proof place. Keep the unit out of the reach of children.

9.6. 

  

Remove batteries from the remote control. Store remote control in an appropriate place.

9.7. 

  

Ensure that the unit is stored in a dry place.

Original Language Version

© Jack Sealey Limited

S

AC9002         Issue 1         19/03/20

fig.8

fig.9

fig.11

fig.10

Содержание SAC9002

Страница 1: ...BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 1 5 Products which require more than 13 amps are supplied without a plug Contact a qualified electrician to ensure that a suit...

Страница 2: ... 5m Max water extraction rate 24L day Noise level 65db A Power 1010W Rated capacity 2640W Refrigerant R290 Suction side pressure 1 3Mpa Supply 230V 50Hz 4 CONTENTS SEE FIG 1 5 INSTALLATION WARNING leave this mobile air conditioner in an upright position for at least 2 hours before first use Ensure that the air conditioner remains in an upright position whilst it is being moved Place the air condit...

Страница 3: ...w by pressing the Fan button on the display The relevant LED will show the setting 6 3 3 The cooling temperature can be set using the up and down arrows and will be shown in the LED display window 6 3 4 Temperatures can be displayed in either Centigrade or Fahrenheit by pressing both up and down arrows simultaneously 6 4 DEHUMIDIFYING MODE 6 4 1 To engage the dehumidifying function press the Mode ...

Страница 4: ...to drain the condensate in the unit otherwise the unit will shut down automatically after the buzzer gives off 5 beeps If the unit is not shut down manually the unit will be restored to the previous operating status automatically once the water is fully drained Or the power may be turned on again to start the unit 6 9 3 DELAY PROTECTION FUNCTION OF THE COMPRESSOR This unit offers restart protectio...

Страница 5: ...the unit DO NOT soak the cleaning cloth 8 MOVING THE UNIT 8 1 To move the unit hold the top of the air outlet on the front of the unit with one hand and the handle position at the top of the back of the unit with another hand Ensure that the unit remains upright DO NOT hold the horizontal louvre by hand 8 2 Leave the unit in the upright position when handling or moving it 8 3 To handle or move the...

Страница 6: ...n Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information BATTERY REMOVAL REMOVE BATTERY FROM REMOTE Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing...

Отзывы: