1.1. ELECTRICAL SAFETY
WARNING!
It is the responsibility of the owner and the
operator to read, understand and comply with the following: You
must check all electrical products, before use, to ensure that
they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure
that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker
(RCCB) should be incorporated in the main distribution board.
We also recommend that a Residual Current Device (RCD) is
used. It is particularly important to use an RCD with portable
products that are plugged into a supply which is not protected by
an RCCB. If in any doubt consult a qualified electrician. You may
obtain a Residual Current Device by contacting your Sealey
dealer. You must also read and understand the following
instructions concerning electrical safety.
1.1.1. The
Electricity at Work Act 1989
requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance Tester
(PAT), at least once a year.
1.1.2. The
Health & Safety at Work Act 1974
makes owners of
electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators.
If in any
doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is
safe before connecting it to the power supply. See 1.1.1. and
1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit
and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none is loose.
1.1.6.
Important:
Ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is fitted
with the correct fuse (see 1.1.10. below).
1.1.7.
DO NOT
pull or carry the appliance by the power cable.
1.1.8.
DO NOT
pull the plug from the socket by the cable.
1.1.9.
DO NOT
use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician.
WARNING!
ELECTRICAL INSTALLATION TO A 3 PHASE
415VOLT SUPPLY MUST ONLY BE CARRIED OUT BY A
QUALIFIED ELECTRICIAN.
1.1.10 This product must be fitted with a 3 phase plug wired as
illustration in (fig.1), wired to an appropriately fused supply.
Connect GREEN/YELLOW wire to Earth ‘E’
Connect BROWN wire to L1 Terminal.*
Connect BLACK wire to L2 Terminal.*
Connect the GREY wire to L3 Terminal.*
*NOTE:
The cable core colours found in the mains cable on this
compressor are consistent with
Amendment 2 to 7671:2001. When
completed, check there are no bare
wires, that all wires have been
connected correctly and the cable
restraint is tight
WARNING!
IT IS ESSENTIAL TO
OBSERVE PULLEY DIRECTION ON
INITIAL START UP, SEE PULLEY
GUARD. IF INCORRECT, STOP
IMMEDIATELY AND CONSULT A
QUALIFIED ELECTRICIAN TO
INVERT 2 PHASES*.
1.1.11
DO NOT
use this product with
an extension cable.
IMPORTANT USER
INFORMATION!
Over-current protection of the power circuit is required in
accordance with 7.2 of EN 60204-1:2006. The supply
disconnecting device to be in accordance with 5.3
of EN 60204-1:2006.
Ask a qualified electrician about compliance.
1.2. GENERAL SAFETY
3
Familiarise yourself with the application and limitations of the
compressor.
3
Ensure the compressor is in good order and condition before
use. If in any doubt do not use the unit and contact an
electrician/service agent.
WARNING!
Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to adjust,
pressure switch or safety valve.
3
Before moving, or maintaining the compressor ensure it is
unplugged from the mains supply and that the air tank pressure
has been vented.
3
Maintain the compressor in good condition and replace any
damaged or worn parts. Use genuine parts only.
Unauthorised
parts may be dangerous and will invalidate your warranty.
INSTRUCTIONS FOR:
COMPRESSOR - 500LTR BELT DRIVE 10hp 2-STAGE
WITH CAST CYLINDERS
MODEL No:
SAC65010B
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
Original Language Version
© Jack Sealey Limited
SAC65010B Issue: 1 - 24/12/14
fig.1
Guide to symbols
Warning:
Electricity
Warning:
Hot Surface
Warning:
Automatic
start up
Wear ear protection
Read the instruction
manual before use
DO NOT
open the air
cock before an air hose
is attached
DO NOT
operate the
compressor with
enclosure displaced
Ensure oil level is
correct before first use