2. INTRODUCTION
4-in-1 Air cooler, heater, air purifier and humidifier. Remote control and panel control. Large 12L water tank supplied with ice pack. Generates
negative ions to purify and sterilise output air. Hi-tech PTC heating element assures safer and rapid heating with two power options
(1000/2000W). Adjustable airflow direction. Three selectable fan speeds. Up to 12 hour timer. Easy to operate and move around on castors.
3. SPECIFICATION
M
odel No.:
............................................................ SAC41.V3
Cooler: ............................................................................
80W
C
ooling Water Tank:
.........................................................
12L
Heater: ...............................................................
1000/2000W
M
aximum Airflow:
.....................................................
485m³/hr
Supply: ...........................................................................230V
M
aximum Flow Rate (F):
........................................
7.5m³/min
F
an Power Input (P): .......................................................
80W
Service Value (SV): .......................................
0.09 (m³/min)/W
Standby Power Consumption (Psb): .............................
0.0W
Fan Sound Power Level (Lwa):
.................................
65dB(A)
Maximum Air Velocity (c): .............................................
10m/s
4. OPERATION
4.1.
Select either Cooling or Heating by use of the lever (Fig.1) on the side of the machine.
4.1.1.
Use the rocker switch on the rear of the unit to turn the power on.
4.1.2.
The LED display will light up and show the current ambient temperature.
4.2.
ON/OFF
4.2.1.
Pressing the ON/OFF button the unit will start the unit running in whichever mode you have selected (See below). Pressing the
button a second time will cause the unit to stop working after approximately 30 seconds. The LED display will show the
current ambient temperature.
4.3.
COOLING MODE
4.3.1.
The unit produces a cooling effect by evaporating water which is contained in a tank in the base of the unit. Before using as a
cooler, the water tank must be filled. Ensure that the unit is unplugged from the mains supply before topping up with water.
4.3.2.
Pull the tank from the unit and pour water into the tank. Check the level of water in the tank is between ‘min’ and ‘max’. For an
increased cooling effect, additionally place ice freezer blocks directly into the tank checking that the water level is still below
the maximum mark when immersed.
4.3.3.
Press the On/Off button and machine will start running.
4.3.4.
If Cooling is selected, the unit starts running and displays the low fan speed symbol and the low level indicator
for Wind/H
eat .
4.3.5.
When Cooling mode is selected, press Cooler button and the Cooling symbol will illumin
ate .
4.3.6.
In cooling mode, the fan speed can be adjusted using the Speed button. There are three speed settings and can be cycled
through by pressing the Speed button. Low speed is indicated
by , medium speed , and high speed .
4.3.7.
The cooling effect has three settings, O
n , intermittent (long interval) and intermittent (short interval) .
Press the Wind/Heat button to cycle though the options.
4.4.
HEATING MODE
4.4.1.
Press the On/Off button and machine will start running.
4.4.2.
If Heating is selected, the unit starts running and displays a single power symbol indicating low power , and the
medium fan speed symbol .
4.4.3.
To set the heating to use full power, press the Wind/Heat button and a second power will display alongside the first.
NOTE:
In Heating mode, the fan speed cannot be altered.
Ion
Wind
Heat
Cooler
Swing
Timer
Speed
O
n/Off
F
ig.1
Original Language Version
© Jack Sealey Limited
S