6.  TROUBLESHOOTiNG  

FAULT

POSSiBLE CAUSE

REMEdY

1A)  Pressure drop in the tank

Air leaks at connections

run  compressor  to  max.  pressure,  switch  off.                   

Brush soap solution over connections and look for 

bubbles. tighten connections showing leaks. 

If problem persists contact Authorised service Agent

1B)  Pressure drop in the tank

Air leaks from safety valve

It should be replaced, unless leaking at a joint 

which can be sealed.

1c)  Pressure drop in the tank

Air leaks from cylinder head gasket

check tightness of head bolts. If leak continues 

contact authorised service Agent

2)  Pressure switch valve leaks when 

     compressor is idle

non-return valve seal defective

empty the air tank. referring to fig.9 remove the 

non-return valve cap (3), spring (2) and seal (1). 

clean the seal and its seat, or if necessary replace 

the seal

3)  Air leaks from tank body or tank welds

Internal corrosion caused by infrequent tank 

draining or non permitted modifications to tank

cannot be repaired

 

diSCONTiNUE USE iMMEdiATELY

4A)  motor stops and will not restart

thermal cut out has operated

Allow unit to cool for 30 minutes before restarting

4B)  motor stops or stalls and will not restart

supply breaker has tripped

A qualified electrician to check breaker and restart. 

If repeated tripping occurs replace the check valve 

or contact authorised service Agent

5)  compressor stops and does not restart

motor failure

contact Authorised service Agent

6A)   compressor does not stop at max. pressure

Pressure switch fault

contact Authorised service Agent

6B)   compressor does not stop at max. pressure

filter clogged

Head gasket or valve fault

replace filter element.

contact Authorised service Agent

7)  compressor noisy with metallic knock

Bearing or piston damage

contact Authorised service Agent

8)  excessive moisture in discharged air

High humidity environment

drain tank after each use

Original Language Version

© Jack sealey limited 2013

Environmental Protection.

recycle unwanted materials instead of disposing of them as 

waste. All tools, accessories and packaging should be sorted, 

taken to a recycle centre and disposed of in a manner which is 

compatible with the environment.

Parts support is available for this product. To obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

sAc32055B/sAc32775B     Issue no: 1 - 01/06/13

fig.9  

See (fig.1) for location and 6.2

Содержание SAC32055B

Страница 1: ... with correct capacity fuse 1 1 7 DO NOT pull or carry the powered appliance by its power supply lead or output cables 1 1 8 DO NOT pull power plugs from sockets by the power cable 1 1 9 DO NOT use worn or damage leads plugs or connections Immediately replace or have repaired by a qualified Electrician These particular compressors are supplied without a mains plug Follow the instructions below reg...

Страница 2: ...r taken in by the compressor air in Air out is always less than air in due to losses within the compressor 2 INTRODUCTION SPECIFICATION 3 Keep children and unauthorised persons away from the working area 7 DO NOT disassemble compressor for any reason The unit must be checked by qualified personnel only 7 DO NOT use the compressor outdoors or in damp or wet locations 7 DO NOT operate within the vic...

Страница 3: ...nk rises and that the compressor stops automatically when the maximum pressure is reached This value is written on the specification plate and may take in excess of 5 minutes The compressor will now operate automatically The pressure switch fig 5 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls below the minimum threshold approximately 2bar 29psi less t...

Страница 4: ...eat or if necessary replace the seal 3 Air leaks from tank body or tank welds Internal corrosion caused by infrequent tank draining or non permitted modifications to tank Cannot be repaired DISCONTINUE USE IMMEDIATELY 4A Motor stops and will not restart Thermal cut out has operated Allow unit to cool for 30 minutes before restarting 4B Motor stops or stalls and will not restart Supply breaker has ...

Страница 5: ...Original Language Version Jack Sealey Limited 2013 SAC32055B SAC32775B Issue No 1 01 06 13 ...

Отзывы: