Страница 1: ... Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity at Work Act 1989 requires that all portable electrical appliances if used on business premises are tested by a qualified electrician using a Portable Appliance Tester PAT at least once a year 1 1 2 The Health Safety at Work Act 19...
Страница 2: ...ves 3 Drain condensation from tank daily and inspect both inside and outside walls for corrosion as stated in the maintenance schedule in section 5 The tank shell must not fall below the certified thickness at any point WARNING If an electrical fuse blows ensure it is replaced with an identical fuse type and rating 3 When not in use store the compressor carefully in a safe dry childproof location ...
Страница 3: ...eet per minute cfm This refers to free air delivered by the compressor air out which varies according to the pressure setting Do not confuse this with the compressor displacement which is the air taken in by the compressor air in Air out is always less than air in due to losses within the compressor 4 1 STARTING THE COMPRESSOR To turn the compressor on use the switch on the top of the pressure swi...
Страница 4: ...mail fig 5 fig 7 fig 8 Fault Cause Remedy Pressure drop in the tank Air leaks at connections Run compressor to max pressure switch off Brush soap solution over connections and look for bubbles Tighten connections showing leaks If problem persists contact Authorised Service Agent Pressure switch valve leaks when compressor is idle Non return valve seal defective Discharge all tank pressure Referrin...