background image

12,000BTU/HR PORTABLE AIR CONDITIONER/
DEHUMIDIFIER/AIR COOLER/HEATER

MODEL NO: 

SAC12000.V4

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 
and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1. 

  

ELECTRICAL SAFETY

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all  

 

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey dealer. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance  

 

Test) tested.

 

Electrical safety information: 

 it is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

IMPORTANT

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

correct fuse - see fuse rating in these instructions.

 

8

  

DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

  

DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or 

             replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

      

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

      

Ensure that repairs are carried out by a qualified electrician.

         

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

B) Connect the BROWN live wire to the live terminal ‘L’.

 

C) Connect the BLUE neutral wire to the neutral terminal ‘N

’.

      

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician.

1.1.5. 

  

Products which require more than 13 amps are supplied without a plug. Contact a qualified electrician to ensure that a suitably rated  

 

supply is available. Ensure that an industrial round pin plug and socket are fitted by a qualified electrician. 

1.1.6.   

If an extension cable reel is used, ensure that it is fully unwound before connection. Use a reel that includes an RCD, an appliance  

 

will be protected by the RCD. The cable core section is important and should be at least 1.5mm

2

. Ensure that the cable of the reel is  

 

appropriate for this product. We recommend the use of 2.5mm² core section cable.

1.2.    

GENERAL  SAFETY

 

9

  

Check that the unit is in sound condition and good working order. Take immediate action to repair or replace damaged parts.

 

  Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

  

 NOTE:

 Appliance is filled with R290.

 

9

 

 

Appliance shall be installed, operated and stored in a room with a floor area larger than 12m².

 

8

  

DO NOT

 perforate any of the components in the refrigerant circuit. Refrigerant gas may be odourless.

 

8

  

DO NOT

 attempt any repairs / maintenance unless suitably qualified.

 

8

 

DO NOT

 stand or place any object closer than 500mm from the unit. 

 

8

  

DO  NOT

 obstruct the air intakes or outlets of the unit, and 

DO NOT

 cover with washed clothes.

 

8

  

DO  NOT 

place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

  

DO  NOT

 operate the unit when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO  NOT 

switch the unit off by disconnecting it from the mains. 

ALWAYS 

switch to the “OFF” position first.

 

8

  

DO  NOT 

remove the float lever from the water collection tank.

 

8

  

DO  NOT 

connect or disconnect the plug from the mains with wet hands.

 

9

  

Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

9

  

Place the unit on a level and stable surface.

 

9

  

To prevent water from freezing, 

DO NOT

 use the unit at ambient temperatures below 0°C.

 

8

  

DO  NOT

 use the unit outside. 

 

9

   Ensure that heating appliances are not exposed to the flow of air from the unit.

 

9

   Before attempting to move the unit, empty the contents of the water tank. Use side carrying handles when moving unit. 

 

9

   Switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.

 

9

   Ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children.

Replacement fuse 

rating:13A

Refer to 

instruction 

manual

S

AC12000.V4  Issue 2 (3) 16/06/22

Original Language Version

© Jack Sealey Limited

Do not cover

Caution: 

Risk of fire

Indoor use only

Содержание SAC12000.V4

Страница 1: ...nt and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 1 5 Products which require more than 13 amps are supplied without a plug Contact a qualified electrician to ensure that a suitably rated supply is available Ensure that an industrial round pin plug and socket are fitted by a qualified electrician 1 1 6 If an extension cable reel is used en...

Страница 2: ...evel 65dB A Power 1337W Cooling 118W Heating Rated capacity 3520W Cooling 2780W Heating Refrigerant R290 Suction side pressure 0 7MPa Supply 230V 50Hz 4 INSTALLATION IMPORTANT Allow the refrigerant to settle for at least 24 hours before using the unit 4 1 EXHAUST HOSE ASSEMBLY 4 1 1 Thread hose adaptor fig 2 onto the hose and then locate adaptor into its housing in the body 4 1 2 Pull the free end...

Страница 3: ...ter one hour the set temperature is increased by 1o C After two hours the set temperature will again be increased by 1o C 5 6 3 When sleep is selected during heat mode after one hour the set temperature is decreased by 1o C After two hours the set temperature will again be decreased by 1o C 5 6 4 After two hours of auto adjustment the set temperature will be kept constant for 10 hours indicators w...

Страница 4: ...pply before cleaning or performing maintenance 7 1 1 Inspect the unit on a regular basis and replace or repair any damaged parts Use recommended parts and an authorised service agent Unauthorised parts may be dangerous and will invalidate the warranty 8 DO NOT use any solvents or abrasive material to clean the plastic exterior of the unit Use only a damp soft cloth for cleaning and dry the unit af...

Страница 5: ...pan See Section 5 10 Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR 01284 757500 01284 703534 sales sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment...

Отзывы: