Sealey SAC05020 Скачать руководство пользователя страница 2

Original Language Version

© Jack Sealey limited

 

8

   do Not

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time    

  after shut down.

 

8

  

do Not 

attempt to move the compressor by pulling the air tool hose. only move the compressor by the handle.

 

8

  

do Not

 use this product to perform a task for which it is not designed.

 

8

  

do Not

 deface the certification plate attached to the compressor tank.

 

8

  

do Not 

cover the compressor or restrict air flow around the machine whilst operating.

 

8

  

do Not

 operate the compressor without an air filter.

 

8

  

do Not

 allow anyone to operate the compressor unless they have received full instructions.

 

  

dANGer! do Not 

direct the output jet of air towards people or animals.

 

‰

 

  WArNiNG!

 The air tank is a pressure vessel and the following safety measures apply:

 

8

  

do Not

 tamper with the safety valve.

 

8

 

  do Not

 modify, weld or alter the tank in any way and 

do Not

 strap anything to the tank.

 

8

  

do Not 

subject the tank to impact, vibration or to heat and 

do Not

 allow contact with abrasives or corrosives.

 

9

  

do

 drain condensation from tank daily and inspect inside walls for corrosion every three months and have a detailed tank   

 

  inspection carried out annually.

 

9

   The tank shell must not fall below the certified thickness at any point. 

 

‰

  

WArNiNG!

 If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.

 

9

   When not in use for a long period, store the compressor carefully in a safe, dry, childproof location.

 

9

   When the compressor is not in use, it should be switched off, disconnected from the mains supply and the air drained from the tank. 

 

importANt WArNiNG

 - Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or   

 

paint overspray will clog the pump intake filter and may cause internal damage to pump/motor components. Please note that any parts  

 

damaged  by any type of contamination will not be covered by warranty.

2. 

 

iNtroductioN

Aluminium cylinder head with cast iron lining gives reduced weight and improved resistance to wear. 

Suitable for general purpose workshop applications. oil free, single piston pump is belt driven by a 

2hp motor and fixed to a vertical type tank, saving space around the workshop. Precision welded 

receiver tank manufactured to meet the Pressure Vessel Directive. Fitted with fully automatic 

pressure cut-out switch and air regulator with gauge. Supplied with handle and wheels for easy 

manoeuvrability. Fitted with ASTA/BS approved non-rewireable plug.

3.  specificAtioN

model no ..................................................................

SAC05030

motor output: ......................................................................2hp

Voltage/Phase:

 ........................................................

230V - 1ph 

Input Current: ....................................................................

6.5A

max. Air displacement: ...................................................

7.3cfm

max. Free Air delivery: ...................................................

5.1cfm

Tank Capacity: .....................................................................

50L

max. Pressure: .....................................................

145psi/10bar

S

ize (W x D x H)

 ........................................

380 x 400 x 875mm

outlet .................................................... Quick release coupling

noise Power: ..................................................................

97dBA

4.  operAtioN

 

‰

  

WArNiNG!

 Ensure that you have read, understood and apply Section 1 safety instructions.

 

importANt

  The use of extension leads to connect this compressor to the mains is not   recommended as the resulting voltage drop  

 

reduces motor, and therefore pump, performance.

4.1. 

  

Take care when selecting tools for use with the compressor. Air tool manufacturers normally express the volume of air required to  

 

operate a tool in cubic feet per minute (cfm). This refers to free air delivered by the compressor (‘air out’) which varies according to the  

 

pressure setting. Do not confuse this with the compressor displacement which is the air taken in by the compressor (‘air in’). ‘Air out’ is  

 

always less than ‘air in’ - due to losses within the compressor.

4.2. 

  

stArtiNG the compressor.

4.2.1.   

The compressor is fitted with a push ON/OFF switch (fig.2). 

4.2.2.   

To turn the compressor ‘ON’ push the switch. To turn the compressor ‘OFF’ push the 

 

switch again.

4.2.3.   

Check that the ON/OFF switch is in the “OFF” position and the regulator tap (fig.2) is 

 

closed (Zero ‘0’ bar, Anti-clockwise). 

   

4.2.4.   

Plug mains lead into mains supply and start the compressor by pushing the ON/OFF switch.

4.2.5. 

  

leave the compressor running with the regulator tap (fig.2) set to maximum pressure.  

 

 

 

make sure that the pressure in the tank rises and that the compressor stops automatically    

 

 

when the maximum pressure value allowed - written on the specification plate is achieved.   

 

 

The compressor will now operate automatically. 

4.2.6. 

  

The pressure switch stops the motor when the maximum tank pressure is reached, and will   

 

 

restart it when pressure falls below the minimum threshold - approx. 2 bar (29psi) less than   

 

 

the maximum pressure.

4.2.7. 

  

Stop the compressor by pushing the 

ON/OFF

 switch 

(fig.2)

. The  compressed air inside the compressor head will flow out, making the  

 

restart easier and preventing the motor from being damaged. 

 

8

  

do Not

, other than in an emergency, stop the compressor by switching off the mains socket, or by pulling the plug out of the socket,  

  as the pressure relief will not then occur and motor damage may result upon restart.

fig.1

fig.2

S

AC05020 | Issue:3 (H,F) 01/08/19

Содержание SAC05020

Страница 1: ...the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician If an extension reel is used it should be fully unwound before connection A reel with an RCD fitted is preferred since any appliance plugged into it will be protected The cable core section is important and should be at least 1 5mm but t...

Страница 2: ...d with fully automatic pressure cut out switch and air regulator with gauge Supplied with handle and wheels for easy manoeuvrability Fitted with ASTA BS approved non rewireable plug 3 specification Model no SAC05030 Motor Output 2hp Voltage Phase 230V 1ph Input Current 6 5A Max Air Displacement 7 3cfm Max Free Air Delivery 5 1cfm Tank Capacity 50L Max Pressure 145psi 10bar Size W x D x H 380 x 400...

Страница 3: ...e compressor slightly towards the drain valve to ensure all condensation drains Close valve after draining condensation and dispose of it safely b Regularly clean dirt and dust away from the safety devices with a clean cloth or blowing with low pressure compressed air Generally keep the compressor clean 5 3 Operations to be carried out every 100 hours Or more frequently if the compressor operates ...

Страница 4: ...e in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information 6 troubleshooting SAC05020 Issue 3 H F 01 08 19 Original Language Version Jack Sealey Limited Fault Cause Remedy Pressure drop in the tank Air lea...

Отзывы: