5. OPERATION
WARNING! Ensure the hose is disconnected from the air supply. DO NOT position the hose in direct sunlight or in areas of
extreme heat or cold. A clearance of 750mm either side of the pivot position is required for a full 180° sweep of the casing.
5.1.
Wall mounting.
5.1.1.
Remove all items from the packaging.
5.1.2.
Using the pivot bracket, item 2, as a template, mark the wall or substantial post, where the hose reel is to be mounted and drill four
10mm diameter holes 50mm deep, 40mm centres horizontally and 164mm vertically. (Suggest 800mm approximately from the floor
to the under edge of the hose reel casing)
5.1.3.
Insert the four plastic plugs, item 4, into the holes and mount the bracket securely, flat face uppermost (fig.1), with the four self tapping
screws, item 3.
5.1.4.
With assistance, offer the hose reel pivot shaft into the pivot bracket, check for full sweep angle. No further fitting required.
5.1.5.
Connect to an air line.
DO NOT
connect directly to an air tool, connect a leader hose to the tool first and then connect the leader hose
to the air hose reel.
5.2.
Extending the hose.
5.2.1.
Pull the hose out slowly to the length required and stop, pause momentarily to enable the ratchet to engage. Operate the air line by
opening the tap or valve.
5.3.
Retracting the hose.
5.3.1.
Close the tap or valve. To release the hose and allow it to automatically rewind, pull the hose out from the locked position and
then release the tension on the hose. Carry the air tool with the hose back to the hose reel housing.
WARNING!
The reel tension is factory set, if any adjustment is required contact an authorised service agent.
6. MAINTENANCE
WARNING! Before attempting maintenance or inspection, vent any pressure remaining in the hose.
To ensure reliable operation, clean the hose and casing regularly.
DO NOT
spray or wet the product, but clean with a damp cloth
and warm water.
DO NOT
use solvents or detergents, as these may permanently damage the item. The hose reel does not require
special maintenance as it is lubricated for life. If the product needs to be opened, consult your nearest authorised service agent.
WARNING: DO NOT attempt to loosen, or remove, any casing screws yourself.
Replacement of the supply hose should be carried out by skilled personnel only, consult your nearest authorised service agent.
STORAGE:
Before storing the air hose, ensure it is clean and dry. Store it in a dark, safe, dry, childproof location, where the
temperature will remain reasonably stable.
7. TROUBLESHOOTING
Fault
Possible Cause
Possible remedy
Hose will not
retract
Hose extended too far and
locked
Open the top lid and turn the reel to free the
lock. (fig.3)
The spring has lost some
torsion
Contact an authorised service agent.
DO
NOT
attempt the repair yourself.
Hose twisted in housing.
Draw the hose from the reel to check.
Torsion (main spring)
fatigued.
Contact an authorised service agent.
DO
NOT
attempt the repair yourself.
fig.3
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
www.sealey.co.uk
Note
: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important
: No Liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
SA821.V2,SA822.V2,SA823.V2,SA824.V2 Issue 2(HF) - 10/07/18
Original Language Version
© Jack Sealey Limited