background image

5.  OPERATION

 

WARNING! Ensure the hose is disconnected from the air supply. DO NOT position the hose in direct sunlight or in areas of  

 

extreme heat or cold. A clearance of 750mm either side of the pivot position is required for a full 180° sweep of the casing.

5.1.

 

Wall mounting.

5.1.1. 

Remove all items from the packaging.

5.1.2. 

Using the pivot bracket, item 2, as a template, mark the wall or substantial post, where the hose reel is to be mounted and drill four    

 

10mm diameter holes 50mm deep, 40mm centres horizontally and 164mm vertically. (Suggest 800mm approximately from the floor   

 

to the under edge of the hose reel casing)

5.1.3. 

Insert the four plastic plugs, item 4, into the holes and mount the bracket securely, flat face uppermost (fig.1), with the four self tapping  

 

screws, item 3.

5.1.4. 

With assistance, offer the hose reel pivot shaft into the pivot bracket, check for full sweep angle. No further fitting required.

5.1.5. 

Connect to an air line. 

DO NOT

 connect directly to an air tool, connect a leader hose to the tool first and then connect the leader hose  

 

to the air hose reel.

5.2. 

Extending the hose.

5.2.1. 

Pull the hose out slowly to the length required and stop, pause momentarily to enable the ratchet to engage. Operate the air line by  

 

opening the tap or valve. 

5.3. 

Retracting the hose.

5.3.1. 

Close the tap or valve. To release the hose and allow it to automatically rewind, pull the hose out from the locked position and  

 

 

then release the tension on the hose. Carry the air tool with the hose back to the hose reel housing.

 

WARNING!

 The reel tension is factory set, if any adjustment is required contact an authorised service agent. 

6.  MAINTENANCE

 

WARNING! Before attempting maintenance or inspection, vent any pressure remaining in the hose. 

 

To ensure reliable operation, clean the hose and casing regularly. 

DO NOT

 spray or wet the product, but clean with a damp cloth   

           

and warm water. 

DO NOT

 use solvents or detergents, as these may permanently damage the item. The hose reel does not require  

 

special maintenance as it is lubricated for life. If the product needs to be opened, consult your nearest authorised service agent. 

 

WARNING: DO NOT attempt to loosen, or remove, any casing screws yourself. 

 

Replacement of the supply hose should be carried out by skilled personnel only, consult your nearest authorised service agent.

 STORAGE: 

Before storing the air hose, ensure it is clean and dry. Store it in a dark, safe, dry, childproof location, where the  

 

 

temperature will remain reasonably stable.

7.  TROUBLESHOOTING

Fault

Possible Cause

Possible remedy

Hose will not 

retract

Hose extended too far and 

locked

Open the top lid and turn the reel to free the 

lock. (fig.3)

The spring has lost some 

torsion

Contact an authorised service agent. 

DO 

NOT

 attempt the repair yourself. 

Hose twisted in housing.

Draw the hose from the reel to check.

Torsion (main spring) 

fatigued.

Contact an authorised service agent. 

DO 

NOT

 attempt the repair yourself. 

fig.3

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

SA821.V2,SA822.V2,SA823.V2,SA824.V2 Issue 2(HF) - 10/07/18

Original Language Version

© Jack Sealey Limited

Отзывы: