3.1.  Air Supply. 

(Recommended hook-up procedure is shown in fig.1.) 

3.1.1. Ensure wrench air valve (or trigger) is in the "off" position before connecting to the air supply.

3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.

3.1.3. 

 

WARNING! 

Ensure the air supply is clean and does not exceed 90psi while operating the

 

wrench. Too high an air pressure and unclean air will shorten the product life due to excessive 

 

wear, and may be dangerous causing damage and/or personal injury. 

3.1.4. Drain the air tank daily. Water in the air line will damage the wrench. 

3.1.5. Clean air inlet filter weekly. 

3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8 

 

metres). The minimum hose diameter should be 1/4” I.D. and fittings must have the same 

 

inside dimensions. 

3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain 

 

that all connections are secure. 

3.2.   Couplings. 

Vibration may cause failure if a quick change coupling is connected directly to the wrench. 

To overcome this, connect a leader hose to the wrench. A quick change coupling may then be used 

to connect the leader hose to the air line recoil hose. See fig.1 & 2. 

3.  PREPARING WRENCH FOR USE

4.  OPERATING INSTRUCTIONS

 

WARNING! Ensure you read, understand and apply safety instructions before use.

4.1.

  Connect the wrench to the air hose as indicated in section 3.

4.2.

  To adjust the wrench head to the desired angle; unlock by rotating the clamp ring (fig.3),  

 

move the head to the desired angle and rotate the clamp ring again to lock wrench head in  

 

position.

 

DO NOT

 operate the wrench without the head being locked in place by the clamp ring.

4.3.

  Place the socket over the subject nut and depress the trigger to operate the wrench. 

4.4.

  To change wrench direction turn the switch on the head of the wrench. (See fig.3)

 

DO NOT

 use any additional force upon the wrench in order to remove a nut.

 

DO NOT

 allow wrench to free run for an extended period of time as this will shorten its life.

 