WarninG!

 

Disconnect wrench from air supply before changing accessories, servicing or 

 

performing maintenance.

 

replace or repair damaged parts. 

Use genuine parts only.   

 

Unauthorised parts may be dangerous and will invalidate the warranty.

5.1.  if the air system does not have an oiler, lubricate the air wrench daily with a few drops of  
 

Sealey air tool oil dripped into the air inlet 

5.2.  Check and top up the gearbox by removing grub screw located under  
 

the impact head

5.3.   Clean the wrench after use. DO NOT use worn, or  

 

 

damaged sockets.

5.4.   Loss of power or erratic action may be due   
 

to the following:

 

a)

  Excessive drain on the air line.  

 

Moisture or restriction in the air    

 

pipe. incorrect size or type of hose  

 

connectors. To remedy check the air  

 

supply and follow instructions in chapter 3. 

 

b

) Grit or gum deposits in the wrench may also  

 

 

reduce performance. if your model has an air strainer (located 

 

in the area of the air inlet), remove the strainer and clean  

 

it. Flush the wrench out with gum solvent oil or an equal mixture  

 

of SAE No 10 oil and paraffin. Allow to dry before use. 

5.5.  For a full service contact your local Sealey service agent.
5.6.  When not in use, disconnect from air supply, clean wrench and store in a    
 

safe, dry, childproof location.

5.  Maintenance

risk of Hand arm Vibration injury. 

The SA6002 Air impact Wrench, when operated in accordance with these instructions and tested in accordance with EN 28662-2: 
1994 results in the following vibration emission declared in accordance with  BS EN12096: 1996. 
Measured vibration emission value: ...................... 5.7m/s²  

uncertainty:  ........................................... 2.28m/s²

these values are suitable for comparison with emission levels of other tools that have been subject to the same test.
this tool may cause hand-arm vibration syndrome if its use is inadequately managed.
recommended Measures to reduce risk of hand-arm vibration syndrome:

This tool should not be used by an individual regularly for more than 188 minutes in any 8 hour period.
This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPortant: 

No liability is accepted for incorrect use of this product. 

Warranty: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inforMation:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole uK Distributor, sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,
iP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

SA6002.V2    issue: 2 - 12/10/09

Отзывы: