background image

p

WARNING!

Disconnect wrench from air supply before changing accessories, servicing or 

performing maintenance. Replace or repair damaged parts. 

Use genuine parts only. 

Unauthorised parts may be dangerous and will invalidate the warranty.

5.1. If the air system does not have an oiler lubricate the air wrench daily with a few drops of 

Sealey air tool oil dripped into the air inlet 

5.2. Check and top up the gearbox by removing grub screw located under the 

impact head.

5.3.  Clean the wrench after use. DO NOT use worn, or 

damaged sockets.

5.4.  Loss of power or erratic action may be due 

to the following:

a)

Excessive drain on the air line. 

Moisture or restriction in the air 

pipe. Incorrect size or type of 

hose connectors. To remedy 

check the air supply and follow 

instructions in chapter 3.

b

) Grit or gum deposits in the wrench may also reduce 

performance. If your model has an air strainer (located in the 

area of the air inlet), remove the strainer and clean it. Flush the 

wrench out with gum solvent oil or an equal mixture of SAE No 10 oil 

and paraffin. Allow to dry before use. 

5.5. For a full service contact your local Sealey service agent.

5.6. When not in use, disconnect from air supply, clean wrench and store in a 

safe, dry, childproof location.

4. OPERATING INSTRUCTIONS

5. MAINTENANCE

p

p

WARNING! Ensure you read, understand and apply safety instructions before use. 

4.1 Only use impact sockets which are specifically designed for use with a impact wrench.

4.2 Connect the wrench to the air hose as in chapter 3.

4.3 Place the socket over the subject nut and depress the trigger to operate the wrench. 

4.4 To change direction use the dial located on the rear, this also controls the power of the 

wrench.

7

DO NOT

use any additional force upon the wrench in order to remove a nut.

7

DO NOT

allow wrench to free run for an extended period of time as this will reduce bearing life.

SA6001 - 1 - 120705

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component

parts without prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this equipment. 

WARRANTY: 

Guarantee is 12

months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our latest catalogue and 

promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

E-mail: [email protected]

Web: www.sealey.co.uk

01284 703534

Sole UK Distributor, Sealey Group

, Bury St. Edmunds, Suffolk.

We, the sole importer into the UK, declare that the product listed here is in conformity with the 

following standards and directives. The construction file for this product is held by the

Manufacturer and may be inspected, by a national authority, upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole

importer into the UK of

Sealey Power Tools.

Declaration of Conformity 

Signed by Mark Sweetman

Air Impact Wrench Model: SA6001

98/37/EC Machinery Directive

93/68/EEC Marking Directive

12th July 2005

p

WARNING! 

Ensure the air supply is clean and does not exceed 

90 psi while operating the wrench. Too high an air pressure and/or 

unclean air will shorten the product life due to excessive wear, and 

may be dangerous causing damage and/or personal injury.

3.1

AIR SUPPLY

3.1.1 Ensure wrench air valve (or trigger) is in the "off" position before 

connecting to the air supply.

3.1.2 You will require an air pressure of 90psi, and an air flow according to specification.

3.1.3 Drain the compressor air tank daily. Water in the air line will damage the wrench.

3.1.4 Clean compressor air inlet filter weekly. Recommended hook-up procedure is shown in fig 1.

3.1.5 Line pressure should be increased to compensate for unusually long air hoses (over 8 

metres). The minimum hose diameter should be 1/4” I.D. and fittings must have the same 

inside dimensions.

3.1.6 Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain 

that all connections are secure.

3.2

COUPLINGS

Vibration may cause failure if a quick change coupling is connected directly to the wrench. 

To overcome this, connect a leader hose to the wrench. A quick change coupling may then 

be used to connect the leader hose to the air line recoil hose. See fig 1 & 2. 

3.

PREPARING WRENCH FOR USE

fig 1

Risk of Hand Arm Vibration Injury. 

The SA6001 Air Impact Wrench, when operated in accordance with these instructions and tested in accordance with EN 28662-2:

1994 results in the following vibration emission declared in accordance with  BS EN12096: 1996. 
Measured vibration emission value:........................5.4m/s

Uncertainty: ............................................3.16m/s

2

These values are suitable for comparison with emission levels of other tools that have been subject to the same test.

This tool may cause hand-arm vibration syndrome if its use is inadequately managed.
Recommended Measures to reduce risk of hand-arm vibration syndrome:

This tool should not be used by an individual regularly for more than 

209

minutes in any 8 hour period.

This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.

fig 2

Отзывы: