Sealey sa19/S.V2 Скачать руководство пользователя страница 2

Original Language 

sA19/s.V2    Issue: 1 - 22/07/11

  

WARNING! Ensure you have read understood and follow the safety instructions in section 1.

4.1.

  screw the sanding disk carrier onto the shaft and tighten with the spanner provided.

4.2.

  Attach a mini sanding disc by screwing it into the centre of the carrier. 

4.3.

  Attach the tool to the air supply, section 2.

4.4.

  to operate the sander, squeeze the trigger.

 

NOTE: The air regulator/speed control may be used as a means of throttle control. See fig.1.

 

Warning!

 

Disconnect the sander from the air supply before changing accessories, servicing or performing any maintenance.

5.1.

  Keep the sander oiled for optimum performance.

 

Lubricate daily with a good grade of air oil such as sealey Ato/500 or Ato/1000. If no air tool oil is used, a teaspoon of oil can be 

 

poured into the tool’s air inlet, or into the hose at the nearest connection to the air supply. then run the sander for a short time.  

5.2.

  Always check the rPM rating of any accessory to ensure it is compatible with the rPM of this sander.

Lightweight and versatile sanding tool suitable for use with sA720 mini sanding pads or 3M® bristle pads and 3M® backing pads. 97° Angle 

head with gearless drive gives optimum performance. fitted with safety release trigger control and variable speed adjustment.  Includes 

backing pad and wrench.

4.  operating instrUCtions

5.  MaintenanCe

3.  introdUCtion & speCiFiCation

Disc size  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mm

Drive thread size. . . . . . . . . . . . . . . . . .

1/4”

-20unc 

free speed. . . . . . . . . . . . . . . . . . . . . . . .22,000rpm

Air consumption. . . . . . . . . . . . . . . . . . . . . . .4.5cfm

operating Pressure  . . . . . . . . . . . . . . . . . . . . . 90psi 

Air inlet size . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP

Weight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    0.6kg

noise power . . . . . . . . . . . . . . . . . . . . . . . .   88dB.A

noise pressure . . . . . . . . . . . . . . . . . . . . . . 100dB.A

Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8m/s²

speCiFiCation:

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMportant: 

no liability is accepted for incorrect use of this product. 

WarrantY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inForMation:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole UK distributor, sealey group, 

Kempson Way, suffolk Business Park

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

risk of hand arm Vibration injury

Air Angle sander (50mm) Model no. sA19/s.V2

 when operated in accordance with these instructions and tested in accordance with Bs En 

28662-1:1993, Iso 8662-1:1988 and 

Bs En Iso 28927-3:2009, 

results in the following vibration emission declared in accordance with Bs 

En 12096:1996. 

Measured vibration emission value: 

1.8

m/s² 

Uncertainty:

 

0.72

m/s²

these values are suitable for comparison with emission levels of other tools that have been subject to the same test.

this tool may cause hand-arm vibration syndrome if its use is inadequately managed.

this is a ‘

no load’

 vibration figure.

A competent person should carry out a risk assessment following HsE guidelines.

Measurement results can be highly variable, depending on many factors, including the operator's technique, the condition of the work 

equipment, the material being processed and the measurement method.

recommended Measures to reduce risk of hand-arm vibration syndrome:

We recommend appropriate safety equipment is utilised and regular breaks for the operator are employed to reduce any residual risk of 

fatigue or repetitive strain injury.

Отзывы: