background image

8

5

10 - 18

The SM225, SM250 & SM275 are circular saws designed to cut ferrous metal - including structural steel - bars and pipes. They 

should not

be

used to cut any other materials. Blade guard, bar stop, integral workpiece vice and coolant system are included.

2. APPLICATION & SPECIFICATIONS

Blade sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .See Blade Chart

Max.cutting capacity  . . . . . . . . . . . . . . . . . . . . . . . . . .See Blade Chart

Max. vice opening (225/250/275)  . . . . . . . . . . . . . . . . .70/100/100 mm

Motor (225/250/275)  . . . . . . . . . . . .0.75/0.9/1.1 kW 230Vac 1ph 50Hz

Motor speed  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1400 rpm

Blade speeds (225/250/275)  . . . . . . . . . . . . . . . . . . . . . .52/52/40 rpm

Mitre cuts (225)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0

O

-45

right

Mitre cuts (250/275)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

O

-0

O

-45

O

Coolant . . . . . . . . . . . . . . . . . . . . . .Water + Sealey SCO/5L soluble oil

Coolant capacity (225/250/275)  . . . . . . . . . . . . . . . . . . . . . . .1/3/3 litre

Oil (gear box) . . . . . . . . . . . . . . . . . . . . .AGIP ACER 320 or equivalent

Oil capacity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.2 litres

Weight (225/250/275) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32/85/98 kg

Sound pressure level- average (225/250/275)  . . .84.2/83.2/83.2 dB (A)

- peak   . . . . . . . . . . . . . . . . . . . . . . .90.6 dB (A)

Specifications:

7

DO NOT force the saw to achieve a task it was not designed to perform.

7

DO NOT allow untrained persons to operate the saw.

7

DO NOT get the saw wet or use in damp or wet locations or areas where there is condensation.

p

WARNING! 

DO NOT use saw where there are flammable liquids, solids or gases such as petrol, paint solvents, waste wiping rags etc.

7

DO NOT operate the saw if any parts are missing or damaged as this may cause failure or possible personal injury.

7

DO NOT remove the safety guard whilst in use.

7

DO NOT attempt to remove a workpiece until the blade has stopped rotating.

7

DO NOT touch the workpiece close to the cut as it will be very hot. Allow to cool.

7

DO NOT leave the saw operating whilst unattended.

7

DO NOT operate the saw when you are tired, under the influence of alcohol, drugs or intoxicating medication.

3

When not in use switch the saw off and isolate from the power supply. 

Blade Chart

Workpiece

SM 225

SM 275

SM 250

Tube

Blade 225mm dia. x 2mm

Blade 275mm dia. x 2.5mm

Blade 250mm dia. x 2mm

Wall thickness

Dia. mm

Tooth pitch mm

No. teeth

No. teeth

Tooth pitch mm

No. teeth

Tooth pitch mm

10 - 80

<2

3

230

280

3

250

3

20 - 80

10 - 80

4 - 10

2 - 4

90

140

110

8

100

8

170

5

160

5

>40

30 - 40

18 - 30

Solid bar

8

5

-

10

-

70

90

140

70

90

12

10

-

80

-

10

110

8

100

8

170

5

160

5

Description:

1. Saw assembly

2. Handle mouldings (2) & screws (3)

3. Micro switch

4. Switch button

5. Control lever

6. End stop

7. Allan keys (sizes 3, 4, 5, 6, 14)

3.1.

Unpack the product and check that all components and tools (five Allan keys) are present and 

undamaged.If any problem is noted contact your supplier immediately. 

3. CONTENTS & ASSEMBLY

fig 1

p

WARNING!

For safe handling and movement use a lift truck or crane. Slings should be located as shown in fig.1.

fig 3

3.2.

Set the saw on a flat, stable work bench, or surface strong enough to support the saw and any workpiece.

Mount the SM250/275 to the working surface (or pedestal) using the mounting holes provided in the base.

3.3.

Assembly of control lever 

3.3.1. Check control lever (fig.2-F) cable slot for burrs or sharp edges - rectify if found - and then screw lever into hole A (fig.3) in saw 

head. Position lever with cable slot to one side and  and the handle fixing hole facing downwards. Tighten lock nut.

3.3.2. Undo the four screws holding the cover ( fig.2-A ) onto the handle B and remove it. Feed the switch cable C into the hole in the end of

the handle and push it through until it emerges from the cover aperture. Connect the cable to the microswitch D as indicated in fig.2 

and seat the microswitch into the moulding with the operating button facing downwards. Retain the microswitch by placing the cover 

over it and fasten the cover with the four screws.

fig 2

SM225, 250 & 275 - (2) - 051102 

Отзывы: