background image

4.  ASSEMBLY / PREOPERATION

4.1. 

  

ASSEMBLY (See fig.1.)

4.1.1. 

  

Screw together the two halves of the lance as shown in fig.2. 

4.1.2.   

Select an appropriate nozzle from the nozzle stowage area. Pull  

 

back the spring loaded sleeve at the end of the lance and insert the 

 

nozzle. Let go of the sleeve and check that the nozzle is firmly gripped 

 

in the fitting. The nozzle selection is colour coded and offers the following 

 options.

 

BLACK  Low pressure wide angle spray for use with detergent.

 

RED 

High pressure, 0° degree spray, 

Very Aggressive

. Use 

 

 

with extreme caution to prevent damage to the surface 

 

 

being cleaned or injury to persons or animals.

 

YELLOW  High pressure, 15° Spray angle, normal cleaning, provides 

 

 

a wide coverage and powerful water stream.

 

WHITE  High pressure, 40° Spray angle, normal cleaning and rinsing,

 

 

provides a less powerful stream of water and is suitable for 

 

 

most general cleaning jobs. 

 

GREEN  High Pressure, 25

°

 Spray angle, normal cleaning.

4.1.3.   

To attach the high pressure hose to the water inlet on the gun, push it 

 

into the inlet on the gun until it is fully seated and tighten as shown in 

 

figs.4 & 5.

4.1.4. 

  

Attach the other end of the high pressure hose to the pump outlet as 

 

shown in fig.6. Push the end of the hose into the pump outlet until it is 

 

fully seated and then tighten to secure. 

 

Connect either a mains water supply hose or the suction hose to the

 

pump inlet as shown in fig.6. USE COLD WATER ONLY.

 Note: 

The water supply hose must be reinforced and have an internal 

 

diameter of 13mm (1/2”). The minimum water supply rate must be at least

 

equal to the washer flow rate.

 

The suction pipe may require priming if drawing water from a level lower than the pump.

4.2. 

  

DETERGENT DELIVERY

4.2.1.   

Attach the BLACK low pressure nozzle to the end of the lance. Remove the cap from a bottle of detergent and place the bottle in the  

 

detergent holder. 

4.2.2. 

  

On the top of the pump outlet is a brass suction injection fitting. Push the detergent input pipe onto the fitting (fig.6) and place the 

  

 

filter on the other end into the container of detergent ensuring that it goes all the way to the bottom. When used with the low pressure  

 

black nozzle detergent will be drawn from the container by suctionic action and will mix 

automatically with thewater from the pump. Use  

 

Sealey General

 Purpose Detergent, 

AK130 (25ltr)

 or 

AK131 (5ltr)

. Traffic Film 

Remover is also available, 

AK132 (25ltr)

 or 

AK133 (5ltr)

4.3. 

  

ENGINE LUBRICATION.

 

THE PRESSURE WASHER ENGINE IS SHIPPED FROM THE FACTORY WITHOUT OIL.

 

DO NOT ATTEMPT TO START THE ENGINE  

 

BEFORE THE SUMP HAS BEEN FILLED WITH THE CORRECT AMOUNT OF OIL. Refer to the section 8.2.

4.4. 

  

FUEL.

4.4.1. 

  

Fill the tank with fresh unleaded petrol fuel. Keep fuel level below the fuel filter which sits in the neck of the tank.

4.5. 

  

PUMP

4.6.    

The pump is supplied empty of oil. Fill with 400ml of 15W-40 oil before using the unit. The combined oil filler cap and dipstick is on top of  

 

the pump.

4.7. 

  

POSITIONING OF UNIT

4.8. 

  

Ideally the unit should be used on level ground. Where this is not possible the unit should not be inclined more than 20° in any one    

 direction.

4.9. 

  

RUNNING IN THE ENGINE

4.9.1. 

  

For the first 20 hours of operation the unit should not be placed under heavy load. After the first 20 hours change the oil.

SAFETY FEATURES

fig.2

fig.4

fig.5

fig.6

BLACK

RED

YELLOW

WHITE

GREEN

fig.3

PWM2500SP | Issue:3 13/07/17

Original Language Version

© Jack Sealey Limited

Содержание PWM2500SP

Страница 1: ... will tend to kick backwards when you first pull the trigger 8 8 DO NOT allow children or untrained persons to operate the washer 8 8 DO NOT connect other appliances to the washer inlet or outlet Only use the supplied or recommended outlet nozzle 8 8 DO NOT use the washer if the water supply hose is damaged Also check that the hose is laid out straight and safely 8 8 DO NOT jam the operating trigg...

Страница 2: ...ety Children should be supervised to ensure that they do not play with the appliance 2 INTRODUCTION Petrol powered pressure washer with recoil starting Ideal for commercial applications with 5mtr pressure hose 1mtr gun and lance and adjustable nozzle Self priming pump makes this unit fully portable and can be used where no mains pressure is available Can draw clean water from water butts and tanks...

Страница 3: ...n pipe may require priming if drawing water from a level lower than the pump 4 2 DETERGENT DELIVERY 4 2 1 Attach the BLACK low pressure nozzle to the end of the lance Remove the cap from a bottle of detergent and place the bottle in the detergent holder 4 2 2 On the top of the pump outlet is a brass suction injection fitting Push the detergent input pipe onto the fitting fig 6 and place the filter...

Страница 4: ...ap in the OFF position Push the fuel tap up to the right to the open position 6 1 6 If the engine is cold move the choke lever to the left to close the choke 6 1 7 Move the throttle lever slightly to the left fig 7 shows the throttle in the full throttle position 6 1 8 Turn the engine switch to the ON position Take hold of the recoil starter handle see fig 1 and pull it slowly until you feel resis...

Страница 5: ...ith nozzle downwards and pull trigger until all water has drained out 7 4 3 Connect a short length of garden hose to the water inlet and using a funnel pour an antifreeze mixture into it 7 4 4 Pull the recoil starter several times to circulate the antifreeze through the pump Continue to add antifreeze and pull the recoil until antifreeze is expelled from the pump 8 MAINTENANCE ENGINE 8 1 Change en...

Страница 6: ...remely flammable and potentially explosive Do not perform maintenance on petrol associated components where there is any source of ignition present such as cigarettes sparks naked flame or hot surfaces 8 5 MAINTENANCE Before each use Check engine oil level Inspect the unit for evidence of oil and fuel leaks After the first month or 20 hours only Change the engine oil Every 50 hours Change the engi...

Страница 7: ...n pump Check inlet hose for correct size or leaks Engine running hot Wrong grade of oil Use recommended oil Oil too high low Adjust oil level to recommended level PWM2500SP Issue 3 13 07 17 Original Language Version Jack Sealey Limited Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR 01284 757500 01284 703534 sales sealey co uk www sealey co uk ENVIRONMENT PROTECTION...

Отзывы: