background image

Original Language Version

© Jack Sealey Limited

min. Features an audible alarm to alert user of low battery/low airflow. Inner hood has protective clear visor to BS EN166 standards. Welding 

helmet has adjustable shade control from 9-13 & 5-8. Fully automatic switching from light to dark on striking arc @ 1/25,000s. Solar panel 

power supply to welding helmet. Contoured design helmet with adjustable headband for added comfort. Suitable for MIG, TIG and ARC welding. 

Complies with BS EN379, EN175, EN166, EN12941 and DIN standards.

3.  SPECIFICATION

Model No:......................................................................................................PWH616

HELMET:

Shade Active: .................................................................................

5-8 & 9-13 Variable

Shade Inactive: .......................................................................................................... 4

G

rinding Function: .................................................................................................. Yes

V

iewing Area: ..............................................................................................

98 x 62mm

O

perating Time Light / Dark:

 .........................................................................

1/25,000s

Operating Temperature: .........................................................................

-5°C to +55°C

POWERED AIR PURIFYING RESPIRATOR:

PAPR Air Flow Settings: ...................................................................

150/180/210L/min

P

APR Lithium Battery Charging Time:

.....................................................

2.5hr approx.

P

APR Filter Classification:

 ........................................................................

TH1 P R SL

PAPR REPLACEMENT PARTS:

Filter cartridge: ............................................................................................

PWH616.F

Lithium battery: ........................................................................................

PWH616.BP

B

lower hose: ............................................................................................

PWH616.BH

HELMET REPLACEMENT PARTS:

B

lock nut .................................................................................................

PWH616.H01

Front Cover Lens ....................................................................................

PWH616.H02

Auto-Darkening Filter Cartridge ..............................................................

PWH616.H03

H

eadband ...............................................................................................

PWH616.H04

S

weat Band

.............................................................................................

PWH616.H05

4.  HELMET 

4.1. 

  

HELMET ADJUSTMENT (fig.1)

4.1.1. 

  

To adjust the fit-to-head, use the handwheel (fig.1.1) on the back of the strap to increase or decrease the head band circumference.

4.1.2. 

  

Further adjustment for fit-to-head can be achieved by increasing or decreasing the length of webbing straps fig.1.2 and fig.1.3.

4.1.3.   

To adjust the distance between the user’s face and the front of the mask, loosen the side thumbwheels and depress the spring loaded  

 

pin on the hinge points (fig.1.4, fig.1.5). Slide the helmet to the desired position and release the pin. There are three locations into  

 

which the spring loaded pin may be seated. Re-tighten the thumbwheels. This should be done one side at a time and both sides    

 

should be located at the same position for proper auto-darkening filter operation. 

4.1.4. 

  

To adjust the viewing angle loosen the side thumbwheels. Depress the tab on item fig.1.6 to disengage it from the rotation lock    

 

(fig.1.7) and set the angle to suit. There are several locations on the rotation lock into

 which the tab may be engaged. Re-tighten the  

 thumbwheels.

1

2

3

5

4

6

7

P

WH616     Issue 1    04/12/20

   fig.1

Содержание PWH616

Страница 1: ...plug with a BS1363 A 13 Amp 3 pin plug If in doubt contact a qualified electrician Class II products are wired with live brown and neutral blue only are marked with the Class II symbol A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connecte...

Страница 2: ...ee equipment warning label and consult your Safety Director and a certified Industrial Hygienist 9 Follow all applicable EN ANSI CSA AS NZS and other regulatory guidelines pertaining to the use of respirators 8 DO NOT use the powered air purifying respirator where there is danger of fire or explosion 8 DO NOT use the powered air purifying respirator in windy conditions or negative pressure inside ...

Страница 3: ...01 Front Cover Lens PWH616 H02 Auto Darkening Filter Cartridge PWH616 H03 Headband PWH616 H04 Sweat Band PWH616 H05 4 HELMET 4 1 HELMET ADJUSTMENT fig 1 4 1 1 To adjust the fit to head use the handwheel fig 1 1 on the back of the strap to increase or decrease the head band circumference 4 1 2 Further adjustment for fit to head can be achieved by increasing or decreasing the length of webbing strap...

Страница 4: ...ecially low amperage argon arc welding Selections between LOW and HIGH are suitable for most of indoor and outdoor welding operations 4 6 DELAY CONTROL 4 6 1 When welding ceases the viewing window automatically changes from dark back to light but with a pre set delay to compensate The delay time can be set from MIN 0 2 sec to MAX 1 0 sec by shade delay control fig 2 4 The minimum delay suits spot ...

Страница 5: ...e front cover lens if it is damaged cracked scratched pitted or dirty Remove the old front cover lens by sliding screw driver blade or similar into the relief under the lens at the bottom of the retaining frame and pull the lens out and replace with new lens Remove any protective film before installing the new one 7 2 HELMET AUTO DARKENING FILTER CARTRIDGE FIG 4 7 2 1 Carefully remove the head ban...

Страница 6: ...an expected 1 Ensure battery pack is fully charged 2 Replace battery 3 Replace charger 4 Check the air filter and replace it if necessary Blower cannot be turned off Press ON OFF button for one second Battery red level light is flashing Charge or replace the battery Danger light is on alarm sounds or blower vibrates Check the blower air flow paths are clear Sealey Group Kempson Way Suffolk Busines...

Отзывы: