6.  INSTALLATION

 

Refer to fig. A

6.1.    

Check that the master switch is turned to OFF, A1 and the water filter is fitted into the pump’s inlet pipe. Screw the snap connector into  

 

place, by hand, without the aid of tools, A2.

6.2.    

Connect the water supply hose to the snap connector. The hose must have an inside diameter of at least1/2” (13mm), A3.

6.3. 

  

Connect the high pressure hose to the pump’s outlet pipe. Press the high pressure hose coupling fully down and then screw into   

 

place by hand without the aid of tools, A4.

6.4. 

  

Connect the high pressure hose to the gun, A5.

6.5.    

Turn the water tap fully on. The water temperature MUST be below 40°C, A6.

 

IMPORTANT 

The machine has to operate with clean water in order to avoid any damage to the machine. 

 IMPORTANT

 

ALWAYS FLUSH

 the machine through thoroughly with cold water after hot water use.

 

IMPORTANT ALWAYS

 release any stored water after use.

6.6.    

Release the gun’s safety catch and keep the trigger pressed, allowing water to flow until all the water has been expelled, A7.

6.7.    

Connect to the mains supply, A8.

6.8.    

Fit the lance into the gun, A9. 

6.9. 

  

FILLING WITH FUEL

6.9.1.   

Fill with the correct fuel indicated on the data plate.

 

IMPORTANT

 

DO NOT

 allow the machine to run out of fuel whilst running so as to not damage the fuel pump.

 

‰

  

WARNING!

 Use of incorrect fuel is hazardous.

6.10. 

FILLING WITH DETERGENT 

6.10.1.  F

ill the detergent tank with the correct product or the washing task being undertaken.

 

‰

  

WARNING!

 Only use liquid detergent, NEVER acid or alkali products. 

7.  OPERATION

7.1. 

  

PRESSURE WASHING

7.1.1.   

Turn electric pump switch ON, see fig.2.2.

7.1.2.   

To wash with Hot water turn the Burner switch ON, see fig.2.1. The burner operates when the trigger is pressed. 

7.1.3.   

Unlock lance, fig.B.2, pull trigger, fig.B.3, hold the lance steady with both hands, fig.B.4.

7.2. 

  

TURN MACHINE OFF

7.2.1.   

Turn off water supply, fig.C.4.

7.2.2.   

Disconnect from mains supply, fig.C.3.

7.2.3.   

Release trigger, fig.C.4 and apply trigger lock fig.C.5.

fig. b

P

W2000HW | Issue:1    25/07/18

Original Language Version

© Jack Sealey Limited

Содержание PW2000HW

Страница 1: ...that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY IMPORTANT The machine has to operate with clean water in order to avoid any dam...

Страница 2: ...ety catch to prevent accidental activation of the jet The safety catch on the gun is not for locking the lever during operation but to prevent its accidental operation WARNING The machine is fitted wi...

Страница 3: ...h and keep the trigger pressed allowing water to flow until all the water has been expelled A7 6 7 Connect to the mains supply A8 6 8 Fit the lance into the gun A9 6 9 FILLING WITH FUEL 6 9 1 Fill wit...

Страница 4: ...released It is advisable to put on the trigger lock on the pistol trigger whenever the machine is stopped in order to prevent unintentional starting 7 4 DETERGENT SUCTION Refer to fig D 7 5 HIGH PRESS...

Страница 5: ...ch off the unit and screw on the high pressure hose again IMPORTANT Failure to comply with the above conditions causes serious mechanical damage to the pump and loss of warranty cover 8 maintenance WA...

Страница 6: ...om the gun and clean the nozzle with the pin provided Supply the machine with water correctly refer to section 6 Remove and clean the filter see MAINTENANCE section Contact an authorised service centr...

Страница 7: ...pted for incorrect use of this product Warranty Guarantee is 12 months from purchase date proof of which is required for any claim Weee Regulations Dispose of this product at the end of its working li...

Отзывы: