 5.  OPERATION

Parts support is available for this product. To obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

   

 

 

       

 

 

Environmental Protection

 

     

  

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to  

   

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely  

   

unserviceable dispose of it according to local regulations.

NOTE:

 It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without 

prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

© Jack Sealey Limited

    Original Language Version 

  

PBS10, PBS40   Version: 1 - 25/02/16

Key:

  1: Valve Block

  2: Cylinder Nut

  3: Safety Valve

  4: Delivery Valve

  5: Regulator Bracket

  6: Regulator Nut

  7: Pressure Gauge

  8: Inlet Valve

 

9: Inlet Connector

10: Push Fit Connectors

11: Air Inlet Tube

12: Delivery Tube

13: Delivery Regulator

14: Filler Cap   

15: Pressure Regulator

5.1

 

WARNING: 

Ensure that the cylinder is not pressurised before removing the

 

filler cap (fig.1.14).

5.1.1.  To fill with blasting medium; unscrew the filler cap and pour the medium into 

 

the cylinder via a funnel. Take care not to over-fill

.

 Replace and tighten the 

 

filler cap. 

DO NOT 

use any other medium than blasting soda in this 

 

unit. 

   

5.2. 

Close the inlet valve (fig.1.8), delivery valve (fig.1.4) and delivery 

 

regulator (fig.1.13). Screw down the regulator cap.

5.2.1.  Connect to the compressed air supply, ensuring that the supply pressure 

 

does not exceed 100psi.

5.2.2.  Open the inlet valve and then increase the cylinder pressure

 

by turning the 

 

regulator cap in an anti-clockwise direction (the regulator can be locked by 

 

pressing the cap down). The cylinder pressure is shown on the pressure 

 

gauge (fig.1.7). 

5.2.3

Open the delivery valve fully.

5.2.4.  Open the delivery regulator slowly until the desired

 

blasting medium flow is achieved. 

DO NOT

 try to regulate the

 

flow by means of the delivery valve. 

5.2.5.  If the flow of blasting medium is not sufficient, increase the 

 

cylinder pressure gradually by means of the main regulator until 

 

a satisfactory flow is achieved. 

5.2.6.  Check the pressure gauge to ensure that the pressure parameters are not

 exceeded.

5.2.7.  Before filling the cylinder, turn the inlet valve off and vent the 

 

pressure from the cylinder by opening the delivery valve 

 

and delivery regulator. The pressure gauge displays the 

 

current tank pressure.

6.1. 

The blasting medium must be used dry; any moisture is 

 

likely to cause intermittent operation or blockage.

6.2. 

When not in use, de-pressurise, close the inlet valve and

 

delivery valve and store in a warm, dry location. Keep away  

 

from children.

6.3.

 

Clean with a moist soapy cloth. 

DO NOT 

use abrasive or solvent cleaners.

 6.  MAINTENANCE