Sealey PP40E Скачать руководство пользователя страница 5

7.  trOuBlesHOOtinG

prOBlem

pOssiBle cause

remeDY

Insufficient penetration or excessive scoria 

settlement.

cutting speed too fast.

touch angle too great.

Work piece is too thick.

electrode and nozzle are worn out.

slow the cutting speed.

Adjust the torch angle.

Confirm work piece thickness and re-check 

technical data.

replace electrode and nozzle.

interruption of cutting arc.

cutting speed too low.

excessive distance between torch and work 

piece.

electrode is worn out.

intervention of the protection system.

increase the cutting speed.

decrease the distance between torch and 

work piece.

replace electrode and nozzle.

check warning lights and take appropriate 

action.

the torch is cutting at tilt when you wish it to 

be perpendicular.

torch position not correct.

Asymmetric wear of nozzle hole and/or wrong 

assembly of torch parts.

re-align the torch.

check assembly (see fig.6) and change 

nozzle if necessary.

excessive wear of nozzle and electrode.

Air pressure too low.

contaminated air (humidity-oil).

excessive pilot arc ignitions in the air.

nozzle holder damaged.

increase air pressure.

check air supply system.

do not casually turn the torch on and off.

change the nozzle holder.

8.  ratinG plate

PP40e | issue2 22/12/16

Original Language Version

© Jack sealey limited

sealey part number

internal wiring information

Plasma symbol

max open circuit voltage

Ac supply details

insulation protection rating

rated supply voltage

equipment safety standard

cutting current range and 

corresponding voltages.
X duty cycle based on 10 mins  

(35% indicates 3.5mins cutting 

6.5mins rest, 100% indicates 

continuous usage.

i

2

, u

2:

current and correspond-

ing voltage.

effective current supplied

max rms current absorbed

Содержание PP40E

Страница 1: ...ble with regard to voltage waveform and frequency The output must be greater than the power consumption of the inverter If any of these requirements are not met the electronics within the inverter may be affected WARNING The use of an unregulated generator may be dangerous and will invalidate the warranty WARNING The inverter may produce voltage surges in the mains supply which can damage other se...

Страница 2: ...40A Duty Cycle 60 40A 100 30A Maximum Cutting Thickness 11mm Air Requirements 250lts min Air Pressure 43 5 58psi Absorbed Power 6 2kW Supply 230V Insulation F Protection IP21S Weight 9 6Kg Consumables PP40E E Electrode short Pack of 5 PP40E N Nozzle short Pack of 5 PP40E D Diffuser Pack of 5 PP40E SC Safety cap Pack of 2 4 set up and controls WARNING Before operating the machine ensure that you re...

Страница 3: ...ivated in this way the problem is normally self rectifying and dependant upon duty cycle time see rating plate in section 9 The switch will re set and the LED will go out and the machine is then ready for use again 4 8 Torch 4 8 1 Although the machine and torch may be fully powered the torch button is the only way to activate the cutting process 4 8 2 To turn the cutting process on the torch butto...

Страница 4: ...flow cooling the nozzle 6 4 2 Other reasons for the arc ceasing are a The distance between the torch nozzle and work piece is too great b You have completed a cut and have continued beyond the edge of a work piece c The waste falls away from the work piece thus increasing the gap 6 maintenance DANGER Ensure that the machine is disconnected from the power supply before performing service or mainten...

Страница 5: ...ion not correct Asymmetric wear of nozzle hole and or wrong assembly of torch parts Re align the torch Check assembly see fig 6 and change nozzle if necessary Excessive wear of nozzle and electrode Air pressure too low Contaminated air humidity oil Excessive pilot arc ignitions in the air Nozzle holder damaged Increase air pressure Check air supply system Do not casually turn the torch on and off ...

Страница 6: ... is maintained between the conduit and the welding power source enclosure 9 6 Maintenance of the equipment The equipment should be routinely maintained according to these instructions All access and service covers should be closed and properly fastened when the welding equipment is in operation The welding equipment should not be modified in any way except for those changes and adjustments covered...