Sealey POWER TOOLS SA652.V3 Скачать руководство пользователя страница 3

 

b)  Grit or gum deposits in the die grinder may also reduce performance. If your model has an air 

 

 

strainer (located in the area of the air inlet), remove the strainer and clean it. Flush the die grinder  

 

 

out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin. Allow to dry before use.

5.4.

  For a full service contact your local Sealey service agent. 

5.5.

  When not in use, disconnect from air supply, clean die grinder and store in a safe, dry, childproof 

 

location.

Danger of Fire/Explosion Hazard

 WARNING! 

The grinding process can produce streams of sparks (especially when grinding metal), which  

  are a potential source of ignition.

 DO NOT 

use the grinder where there are flammable liquids, solids or gases.

 DO NOT 

allow grinder sparks to make contact with the operator’s clothing or any other fabric such as  

  cleaning rags. Fabrics contaminated with inflammable materials such as petrol, oil, grease, paint and  

  solvents are a particular fire hazard.

 

To reduce the risk of clothing catching fire the operator should wear wool or cotton outer garments treated  

  with a fire retardant in preference to man-made fibres.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SA652.V3    Issue: 1 - 22/09/11

Risk of Hand Arm Vibration Injury 

Air Die Grinder Midi Size Straight. Model No: SA652.V3

, when operated in accordance with these instructions 

and tested in accordance with BS EN 28662-1:1993, ISO 8662-1:1988 and BS EN ISO 8662-13:1997 results 

in the following vibration emission declared in accordance with  

BS EN12096:1996.  

Measured vibration emission value:

 1.5m/s² 

Uncertainty:

 0.6m/s²

These values are suitable for comparison with emission levels of other tools that have been subject to the 

same test.

This tool may cause hand-arm vibration syndrome if its use is

 inadequately managed.

This is a ‘

NO LOAD’

 vibration figure.

A competent person should carry out a risk assessment following HSE guidelines.

Measurement results can be highly variable, depending on many factors, including the operator's technique, 

the condition of the work equipment, the material being processed and the measurement method.

Recommended Measures to reduce risk of hand-arm vibration syndrome:

We recommend appropriate safety equipment is utilised and regular breaks for the operator are employed to 

reduce any residual risk of fatigue or repetitive strain injury.