Sealey POWER TOOLS SA50.V2 Скачать руководство пользователя страница 3

 

WARNING!

 Disconnect needle scaler from air supply before changing accessories, servicing or performing  

 

maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be  

 

dangerous and will invalidate the warranty.

 

Note:

 Numbers in brackets refer to item numbers in the parts diagram.

5.1.

  To replace the needles, remove the large circlip from the back opening of the main sleeve and loosen the  

 

three grub screws. Take hold of the sleeve and press the needles firmly onto a hard surface to ease the  

 

plastic retainer out of the sleeve. Remove the hammer followed by the needle supporter, needles and the  

 

spring. Remove the old needles from the needle supporter and replace them with a new set. Reassemble  

 

the scaling head in the reverse order to that described above. Refer to the parts diagram. Screw the  

 

reassembled scaling head back onto the pistol body.

5.2.

  lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air inlet.

5.3.

   Clean the needle scaler after use. 

5.4.

   loss of power or erratic action may be due to the following: 

 

a)  Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose  

 

 

connectors. To remedy check the air supply and follow instructions in Section 3. 

 

b)  Grit or gum deposits in the needle scaler may also reduce performance.  Flush the needle scaler out  

 

 

with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin. Allow to dry before use.  

5.5.

  For a full service contact your local Sealey service agent. 

5.6.

  When not in use, disconnect from air supply, clean needle scaler and store in a safe, dry, childproof  

 

location.

5. 

MAINTENANCE

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SA50.V2    Issue: 1 - 30/05/12

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to 

www.sealey.co.uk, email [email protected] or phone 01284 757500.

Risk of Hand Arm Vibration Injury

The Air Pistol Needle Scaler Model No. SA50.V2 when operated in accordance with these instructions and 

tested in accordance with BS EN 28662-1:1993, ISO 8662-1:1988 and BS EN ISO 28927-9:2009 results in the 

following vibration emission declared in accordance with BS EN 12096:1996.

Measured vibration emis

sion value:

 13.4m/s² 

Uncertainty:

 5.4m/

These values are suitable for comparison with emission levels of other tools that have been subject to the 

same test.

This tool may cause hand-arm vibration syndrome if its use is inadequately managed.

Recommended Measures to reduce risk of hand-arm vib

ration syndrome:

This tool should not be used by an individual regularly for more than 34.1 minutes in any 8 hour period.

This duration of use should be reduced if the individual is exposed to hand-ar

m vibration from other sources.

Отзывы: