Sealey Power Tools GSA02 Скачать руководство пользователя страница 2

INSTRUCTIONS FOR: 

1/2”SQ AIR IMPACT WRENCH

MODEL No: 

GSA02

Original Language Version

GSA02 Issue:4(SP)-26/09/13

For recommended hook-up, procedure is shown in figs.1 & 2.

3.1.  Air Supply

 

3.1.1. Ensure wrench air valve (or trigger) is in the "off" position before connecting to the air  

 supply.

3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.

3.1.3. 

 

WARNING! 

Ensure the air supply is clean and does not exceed 90psi while operating  

 

the wrench. Too high an air pressure and unclean air will shorten the product life due to  

 

excessive wear, and may be dangerous causing damage and/or personal injury. 

3.1.4. Drain the compressor air tank daily. Water in the air line will damage the wrench. 

3.1.5. Clean compressor air inlet filter weekly. 

3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8 

 

metres). The minimum hose diameter should be 1/4” I.D. and fittings must have the same 

 

inside dimensions. 

3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain 

 

that all connections are secure. 

3.2. Couplings. 

 

Vibration may cause failure if a quick change coupling is connected directly to the wrench.  

 

To overcome this, connect a leader hose to the wrench. A quick change coupling may  

 

then be used to connect the leader hose to the air line recoil hose. See figs.1 & 2. 

3. 

PREPARING WRENCH FOR USE

4.      OPERATING INSTRUCTIONS

 

WARNING! Ensure you read, understand and apply  

 

safety instructions before use.

4.1.

  Only use impact sockets which are specifically designed for  

 

use with an impact wrench.

4.2.

  Connect the wrench to the air hose as in Section 3.

4.3.

  Place the socket over the subject nut and depress the  

 

trigger to operate the wrench. 

4.4.

  To change drive direction turn the air regulator on the rear  

 

of the body to the desired direction. (fig 3)

4.5.

  The flow of air may be regulated by adjusting the air    

 

regulator on the rear of the body, between 1 low power and  

 

3 full power.

 

DO NOT

 use any additional force upon the wrench in order  

 

to remove a nut.

 

DO NOT

 allow wrench to free run for an extended period of  

 

time as this will shorten its life.

fig.1

fig.2

fig.3

Отзывы: