background image

3.    ASSEMBLY INSTRUCTIONS

Remove parts from packing and take items out of the tank. Before assembly check parts to ensure they are complete and not damaged.
3.1.    Close lid (4) of tank (1), gently and turn unit upside down. 

Rest tank on a clean soft surface (i.e. cardboard) ensuring lid is secured in the closed postion.

3.2.    Attach the four legs (21) to the tank brackets with the pan head screws, spring washers and hex nuts (22, 23, 24) 

but do not tighten

3.3.

Place the lower shelf (20) between the four legs (21) with flat surface facing downward and fix with washers, hex nuts and screws (22, 23, 24). 

3.4.

With the legs pressed tightly against the lower shelf, tighten all the screws commencing with those attaching the shelf.

3.5.

Hold the lid closed and stand the assembled unit upright. Open the lid 

but do not extend the lid too far.

3.6.

Place the tank work shelf (42) on the two welded supports located inside the tank.

3.7.

Remove the self tapping screws from the pump housing cover of the pump unit (A) and check to see if there is any supporting packing inside. If so, 
remove the supporting packing and replace the cover.

3.8.

Place the pump into the tank unit and pass the switch unit through the slot in the cleaning tank side A. As the unit protrudes through the slot secure it by 

placing the underside lip over the edge of the tank. Attach the flexible pipe (27) to the pump assembly.

Refer to Parts List & Diagrams for item numbers.

4.  OPERATING INSTRUCTIONS

p

WARNING! Wear safety clothing, eye protection and gloves and ensure you read, understand and apply the safety instructions in Section 1.

4.1.

Ensure the unit is located on a firm level surface in a well ventilated area and is switched off and unplugged from the mains power supply.

4.2.

Fill the tank with Sealey solvent - maximum 50 litres. Minimum level 

must

cover pump inlet - approx. 40 litres. Follow the solvent instructions on the

packaging.

4.3.

Plug the machine into the power supply and switch the unit on. The cleaning agent will flow through the flexible tube. 

4.4.  Place parts to be washed into the basket, or directly into the tank. Direct solvent flow onto parts. Heavily soiled items may be left to soak before cleaning.
4.5.

Do not leave the unit operating unattended. Check the fluid level does not fall below the pump inlet. 

4.6.  When cleaning is complete remove all parts whilst ensuring the minimum of cleaning agent spillage.
4.7.

Switch off the unit, close the lid and disconnect the unit from the mains power supply.  Clean up any spillage.

4.8.

Dispose of waste liquids in accordance with local authority regulations.

IMPORTANT! 

The SM19.V2 has an anti-fire device built into the unit. In the event of a fire the lid will automatically close. 

DO NOT prop the lid open as this

will prevent the automatic safety feature from operating.

Once actuated, the fire detection device cannot be re-used and must be replaced before further

use.

3

When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from closing fully if, and when, the 

fusible link activates.

5.  MAINTENANCE

5. 1. Clean the inside of the tank at regular intervals and keep the main body of the unit clean.
5. 2. Regularly wash the pump filter in clean degreaser and replace if necessary.
5. 3. Ensure that all screws and bolts are kept tight. 

Declaration of Conformity 

We, the sole importer into the UK, declare that the product listed here is

in conformity with the following standards and directives.

The construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to

contacting Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.

Parts Cleaning Tank

Model: SM19.V2

73/23/EEC Low Voltage Directive

89/336/EEC EMC Directive

98/37/EC Machinery Directive

93/68/EEC CE Marking Directive

Signed by Mark Sweetman

04 October 2005

01284 757500

01284 703534

E-mail:

[email protected]

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this equipment.

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor,

Sealey Group,

Bury St. Edmunds, Suffolk.

2.     SPECIFICATION

Pump Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200l/h

Max Tank Capacity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50l

Motor Power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25W

Power Supply  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V

Overall Height x Length x Width  . . . . . . .880 x 810 x 540mm

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24kg

Solvent type  . . . . . . . . . . . . . . . . . . . . . . . . . . .Water soluble