Sealey PC300BL Скачать руководство пользователя страница 3

4.2.    

Assembly. (fig.2)

4.2.1.   

Ensure the mains plug is disconnected. (fig.2.1).

4.2.2. 

  

Undo clasps. (fig.2.2) 

.

4.2.3.   

Lift off the top section assembly and filter assembly. Remove contents from inside the container. (fig.2.3) (fig.2.4) (fig.2.5).

4.2.4. 

  

Check filter components are complete in the order as shown. (fig.2.6).

4.2.5.   

Replace the filter assembly and top section assembly onto the container. 

(fig.2.7).

4.2.6. 

  

Align up the top section with the clasps and snap into place by applying pressure at the mid point of the clasps. (fig.2.8)

4.2.7.   

Attach hose rack to the corresponding position on head assembly. (fig.2.9). 

4.2.8.   

Insert handle into corresponding position on top cover. (fig.10).

4.2.9. 

  

Insert the large end of the hose into the front inlet of the container and lock in place by turning clockwise a quarter turn. (fig.2.11).

4.2.10.  Choose the desired extension tubes and nozzle and connect onto the hose. (fig.2.12) (fig.2.13).

5.  OPERATION

 

‰

  

WARNING!

 Ensure you read, understand and apply Section 1 ‘Safety Instructions’. Reminder: 

DO NOT

 vacuum hazardous substances.  

  Use of an incorrect cartridge filter will invalidate your warranty.

5.1.    

Dry Vacuuming. (fig.3)

5.1.1.   

Ensure the machine is unplugged from the power supply. (fig.3.1)

5.1.2.   

Loosen clips (fig.3.2) and remove the top section and filter assembly. (fig.3.3) (fig.3.4)

5.1.3.   

Check that filter components are present and assembled correctly. (fig.3.5).

5.1.4. 

  

Place assembled unit into the body (fig.3.6) and clip in place using side clips (fig.3.7).

5.1.5.   

Connect hose to body and rotate clockwise for a quarter of a turn to lock in place.(fig.3.8).

5.1.6.   

Assemble required tube and hose arrangement. (fig.3.9) (fig.3.10).

5.1.7. 

   Plug into power supply (fig.3.11). Turn on and commence cleaning. (fig.3.12) (fig.3.13).

5.1.8. 

  

When you have completed vacuuming, press the switch to ‘Off’

Original Language Version

© Jack Sealey Limited

fig.3

P

C300BL   Issue 2 (2,3)  7/3/19

Содержание PC300BL

Страница 1: ...e earth terminal E B Connect the BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 9 Disconnect the cleaner from the power supply before servicing changing a...

Страница 2: ... release clasps and blower Supplied with a 4 5m cable and approved plug hose assembly metal telescopic tube wet and dry floor nozzle crevice tool and multi brush 3 SPECIFICATION Model No PC300BL Motor 230V 1200W Max Vacuum Pressure 180mbar Air Flow 158m3 h Container 30ltr Weight 11kg Vac Accessories Ø35mm Filter Dry PC300BLPF Filter Wet PC300BLFF10 Pack of 10 4 ASSEMBLY 4 1 Carton content fig 1 4 ...

Страница 3: ...red extension tubes and nozzle and connect onto the hose fig 2 12 fig 2 13 5 OPERATION WARNING Ensure you read understand and apply Section 1 Safety Instructions Reminder DO NOT vacuum hazardous substances Use of an incorrect cartridge filter will invalidate your warranty 5 1 Dry Vacuuming fig 3 5 1 1 Ensure the machine is unplugged from the power supply fig 3 1 5 1 2 Loosen clips fig 3 2 and remo...

Страница 4: ...3 1 Ensure machine is disconnected from power supply 5 3 2 Remove HEPA filter from filter arrangement 5 3 3 Check that filter components are assembled correctly fig 5 1 5 3 4 Install filter assembly into cleaner body fig 5 2 5 3 5 Install top assembly and lock in place fig 5 3 5 3 6 Connect to power supply and power on fig 5 4 fig 5 5 5 3 7 When maximum capacity is reached the machine will stop ru...

Страница 5: ...cuum followed by Auxiliary power 5 5 7 The vacuum will switch off when power is not being drawn through by the auxiliary device within approximately 10 seconds 6 MAINTENANCE 6 5 1 Ensure the machine is unplugged from the power supply 6 5 2 Disconnect the hose from the container 6 5 3 Undo the clasps and remove motor head from the container 6 5 4 Clear out any dirt or debris from the container and ...

Страница 6: ...orted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter data...