4. SET-UP
Model No.
. . . . . . . . . . . . . . . . . . . .
PC2351
Max Pressure . . . . . . . . . . . . . . . . . . . 95bar
Effective Cleaning Power . . . . . . . . . .2300psi
Water Flow . . . . . . . . . . . . . . . . . . . 360ltr/hr
Motor Power . . . . . . . . . . . . . . . . . . . . 1600W
Input Voltage/Current . . . . . . . . . . . . 230V/7A
Rec. Power Supply. . . . . . . . . . . . . . . . . .13A
Hose Length . . . . . . . . . . . . . . . . . . . . . . 3mtr
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . 7kg
3.1. SPECIFICATION
4.1
Connecting the water supply.
Use a reinforced hose pipe with
an internal diameter of 1/2” and connect to the mains water
supply. Before attaching the hose to the pressure washer flush
the hose through with some clean water to remove any foreign
matter from within the hose. Attach a push fit hose connector to
the water inlet on the machine (fig.1).
4.2
Connecting the high pressure hose.
Attach the high pressure
hose as indicated in fig.1, ensuring the connector is tight.
Turn on the water supply.
4.3
Assembling the lance and nozzle.
Push the lance into the gun as shown in fig.2 and turn 90
°
until
it locks into place.
WARNING!
Ensure the nozzle is locked into position, failure to
ensure this could result in the nozzle being ejected under high
pressure when operating the gun.
WARNING!
Ensure the On/Off switch is in the 'Off' position.
4.4
Connect to supply.
Using an RCD plugged into a 13A mains socket, DO NOT turn
the power on unitll prcedure 5.3 has been carrided out..
DO NOT touch the plug with wet hands.
Original Language Version
PC2351 Issue: 1 - 28/05/10
5. OPERATION
Important! The washer motor will stop as soon as the gun trigger is
released and will restart when the trigger is squeezed. Always allow
at least 5 seconds between releasing the trigger and restarting.
5.1.
Primary checks.
Check that the inlet filter is clean; pump
delivery and pressure will be reduced if blocked. Never use the
machine without a filter (which is fitted inside the water inlet
connector, see fig.1). Ensure that the water supply, high
pressure hose and gun are correctly connected, and that air can
freely circulate around the washer.
5.2
Operation of safety catch
. To prevent inadvertent operation of
the unit the safety catch should always be engaged when the
gun is not in use. Turn the catch 90° away from the trigger to
lock it, towards the trigger to unlock it (fig.3).
5.3
Bleeding The Gun
It is very important to bleed the gun before using the pressure
washer. Squeeze the trigger BEFORE turning the electrical
supply on. This allows any air trapped inside the pressure
washer and gun to be removed before using the unit. Continue
holding the trigger for approximately one minute to allow any
excess air out of the unit. Water will flow through the gun at low
pressure during this procedure.
5.4
Operating the machine.
5.4.1 Hold the spray gun firmly to counteract the recoil caused by the
high pressure of the water. Before switching on ensure that the
lance is not directed at people, objects or animals prior to being
directed at the object to be cleaned.
5.4.2 It is recommended that the trigger is depressed before switching
on the unit before every use. This reduces the back pressure
and amperage draw which prevents fuses blowing.
5.4.3 Switch the machine on by turning the switch to the 'On' position
as shown in fig.1. Release the handle safety catch (fig.3).
Point the lance at the object to be cleaned and fully depress the
trigger. When the trigger is released the motor will automatically
switch off.
WARNING!
Ensure you read, understand and apply
Section 1 safety instructions.
WARNING!
Dry running can seriously damage the unit.
WARNING! Use washer on a flat, levelled surface, in an
upright position. Failure to do so will invalidate your
warranty. Never lay the washer down during use.
WARNING!
DO NOT leave washer switched on for more
than 15 minutes without operating trigger.
fig.1
fig.2
fig.3