background image

6tonne vertical type log splitter
550mm capacity

model no:

 ls550v

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  saFety

1.1. 

  

electrical saFety

 

‰

  

Warning!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical  

 

products. You may obtain an RCd by contacting your local Sealey stockist. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

electrical safety information, it is important that the following information is read and understood.

1.1.1.   

ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

 

correct fuse - see fuse rating in these instructions.

 

8

   Do  not

 pull or carry the appliance by the power cable.

 

8

  

Do not

 pull the plug from the socket by the cable. 

 

8

   Do  not

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or

 

replaced immediately by a qualified electrician.

 

‰

  

Warning!

 Before starting any repair, maintenance or cleaning always disconnect the power.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

 If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

        

 Ensure that repairs are carried out by a qualified electrician.

        

 Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

 a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

 b) Connect the BROWN live wire to the live terminal ‘L’.

 

 c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

 ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

 Sealey recommend that repairs are carried out by a qualified electrician.

1.2.    

saFety  anD maintenance

 

9

   Keep the log splitter clean for best and safest performance.

 

9

   maintain the

 

log splitter in good condition (use an authorised service agent).

 

9

  Prior to every use check all electrical connections, hydraulic pipes, hoses and safety / stopping devices.

 

9

   Use a qualified person to lubricate and maintain the log splitter.

 

8

  

Do not

 use brake fluid to top up hydraulic unit. 

 

8

  

Do not

 operate the log splitter if damaged.

 

9

   Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

1.3.    

WorKsHop/environmental  saFety

 

9

   locate the log splitter on dry, level and solid ground in a suitable work area with adequate lighting. Fix securely in place using anchor bolts.

 

9

   Keep the area clean and tidy and free from unrelated materials. 

Do not

 leave tools, logs or other items lying around where they could  

  become a tripping hazard.

 

8

  

Do not

 operate the log splitter in wet or damp areas or expose it to rain.

 

8

  

Do not

 operate the log splitter in areas where fumes from paint, solvents, or flammable liquids pose a potential hazard. 

1.4.    

operator saFety

 

 

9

   Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.

 

9

   Wear protective, electrically non conductive gloves.

 

9

   Always wear safety goggles. everyday spectacles are not sufficient protection.

 

9

   maintain correct balance and footing, 

Do not

 over-reach. ensure the floor is not slippery and wear non-slip, protective footwear.

 

8

  

Do not

 allow untrained persons to operate the log splitter.

 

8

  

Do not

 operate the log splitter with the guards or guides removed.

 

8

  

Do not

 operate the log splitter when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

Do not

 attempt to load a log until the log pusher has returned to the stop position. 

 

9

   Stay alert and always pay attention to the movement of the machine and the work piece.

 

9

   The log splitter must always be operated by one person only.

Original Language Version

© Jack Sealey limited

Refer to 

instruction

manual

Wear protective 

gloves

Wear eye 

protection

Wear ear 

protection

Wear protective 

clothing

 

Warning!

 

Warning!:

 no reaching 

in.

Keep out of 

rain

Wear safety 

footwear

Recommended fuse rating

13 Amp

l

S550V     Issue 2 (2)       02/10/19

Содержание LS550V

Страница 1: ...the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 SAFETY and maintenance 9 9 Keep the log splitter clean for best and safest performance 9 ...

Страница 2: ...ver all possible conditions and situations that may occur It must be understood that common sense and caution are factors which cannot be built into this product but must be applied by the operator 2 introduction Safe and easy way to split logs offering continuous sizing and up to 6tonne of pressure Adjustable wedge allows workpiece to be as near to wedge as possible minimising splitting time Feat...

Страница 3: ... 3 1 Re tighten the locking knob to firmly hold support table in place fig 3 2 5 3 CONTROL LEVER AND GUARD ASSY fig 1 2 fig 4 5 3 1 Insert M10 x 25 bolts and washers into holes at end of guard tubes fig 4 1 5 3 2 Locate control lever section into slot at end of control arm fig 4 2 5 3 3 Place large flat washer supplied between lever support bracket and control lever section and secure firmly in pl...

Страница 4: ...ge or pulling 6 2 2 In low temperature conditions preheat the hydraulic oil by running the motor under no load for 15 minutes prior to commencing work 6 2 3 Before starting the motor open the Air Bleed fig 8 loosen the oil tank cap a few turns Re tighten cap when machine is not being used to avoid spillage 6 2 4 Before splitting any logs you must check that the safety feature of two handed operati...

Страница 5: ...0MLS or 5ltr containers Part no HJO5LS 7 2 1 Ensure the log splitter is disconnected from the mains power supply 7 2 2 Ensure that no dirt or debris enters the oil tank 7 2 3 Unscrew the oil filler cap which has a dipstick attached to it The oil should reach the top of the flattened portion of the dipstick which is equivalent to the oil being 1 to 2cm lower than the upper surface of the tank 7 2 4...

Страница 6: ...s according to local regulations Weee Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually improv...

Отзывы: