background image

WARNING: Unplug from the mains power supply before performing maintenance or service.

7.1

 

Ensure the welder and cable are in sound condition and good working order.

7.2

 

We recommend that you have your welder serviced on a regular basis by an authorised service agent.

 

During any inspection of the inside of the machine for repairs or cleaning the following checks should be made.

7.2.1  Remove dust and  metallic particles deposited on the transformer and on internal walls etc, using a jet of dry compressed air 

 

(max 10bar). Do not direct the jet of compressed air onto the electronic circuit boards; clean them with a very soft brush if necessary.

7.2.2  Check the wiring for insulation damage or loosened/oxidised connections.

7.2.3  Check that the screws, connecting the flexible element to the transformer and to the upper arm supports, are tightened up and there   

 

are no signs of oxidation or overheating.

7.2.4  Replace or repair damaged parts. 

Use recommended parts only, unauthorised parts may be dangerous and will invalidate the  

 

 

warranty.

7.3

 

Keep the welder clean for best and safest performance. Do not clean with water, strong solvents, paint thinners or gasoline.

7.4

 

If welding performance is poor make the following preliminary checks. 

7.4.1  When the welding/clamp lever is depressed make sure that the spigot at the end of the handle on the underside, actually touches and  

 

presses the microswitch thus turning on the welding current.

7.4.2  Check the security and condition of the arm holder clamps and screws and the electrode clamps and screws. If these are loose or    

 

oxidized it will effect the efficiency of the welder.

7.4.3  Check that the welding parameters are correct in terms of welding time, electrode pressure and diameter.

7.4.4  If these checks do not reveal the source of the problem take the welder to an authorised service agent

  7.  MAINTENANCE

fig. 6

6.2 

Thermostatic protection LED indicator.

 

When all the LEDs on the control panel go off and the two welding mode LEDs  ( 

See fig.5-4

 ) begin to flash  

 

alternately this indicates that the transformer is beginning to overheat and the thermal cut out has operated.  

 

  Allow the welder to cool for at least 5 minutes before attempting to weld again. 

6.3 

Spot welding with H-3000 Electronic Timer ). 

 

Adjust the welding time by using the control mounted on the rear of the unit.

 

See fig.6-9

 )

6.4

 

SPOT WELDING PROCEDURE.

 

 

WARNING!

 

Ensure that you read and understand the safety instructions in Section 1. 

 

Use welder in a suitable working area. Keep area clean and tidy, free from unrelated materials and ensure there is adequate lighting.

 

DO NOT allow untrained persons to operate the welder.

6.4.1  Ensure that you are fully prepared with all workpieces securely held and presented ready for spot welding.

6.4.2  Ensure that the welding arms and electrodes are correctly set up for the thickness you intend to weld. (

 See Sections 5.1 & 5.2 

)

6.4.3  Ensure that you have correctly set the clamping pressure for the thickness you intend to weld.  ( 

See Section 5.3

 ) 

6.4.4 

Turn on the mains power supply.

6.4.5  On Model H-3000 set the appropriate welding time using the knob on the back face of the unit.  ( 

See Section 6.3

 )

6.4.6  On Model H-3000S set the welding time, welding thickness, and welding mode as required using the control panel on the 

   

 

 

side of the unit. ( 

See Section 6.1

 )

6.4.7  Manoeuvre the unit so that the workpiece is between the arms. Allow the lower electrode to bear on the underside of the sheets to be welded.

 

Depress the welding lever until the upper electrode makes contact with the metal. Pause and check that the electrodes are positioned where    

 

the weld is required. When satisfied continue to depress the lever to clamp the sheets together until the lever reaches the end of its travel and   

 

operates the microswitch which turns on the current.

6.4.8  Do not release the clamp lever immediately but pause for a few moments first. This will give the weld improved mechanical  

 

 

characteristics.

6.4.9  When all welds are completed turn off the mains power supply. Disconnect the unit and clean it . Store in a dry and safe environment  

 

until next required.

 

(The effectiveness of spot welds should occassionally be tested to ensure you are using the right settings. When two spot welded sheets are    

 

separated the area of the spot weld itself should not tear apart but remain attached to one of the sheets indicating that the weld is stronger than  

 

the surrounding sheet.) 

Содержание H-3000

Страница 1: ...r supply leads plugs and all electrical connections for wear and damage You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices An RCCB Residual Current Circuit Breaker should be incorporated in the main distribution board We also recommend that an RCD Residual Current Device is used with all electrical products It is particularly important to use ...

Страница 2: ...0 x 185 Plug and Socket 16A 16 32A Delayed Mains Fuses 16A 25A Max spot weld thickness 1 1mm 2 2mm Min rest period between welds 20seconds 20seconds Maximum clamping force 120kg 120kg Projection of arms 120mm 120mm 3 TECHNICAL SPECIFICATION 4 ELECTRICAL CONNECTIONS WARNING Ensure that you read and understand the safety instructions in Section 1 4 1 Connection to mains power supply Before making an...

Страница 3: ...e locking bolt 5 3 Adjusting the pressure exerted by the electrodes Refer to figs 3 4 The pressure exerted by the electrodes onto the workpiece can be adjusted by altering the spring pressure adjuster underneath and within the handle using the 6mm Hex key provided fig 3 1 To increase the pressure turn the adjuster clockwise To decrease the pressure turn the adjuster anticlockwise On the top face o...

Страница 4: ... cut out has operated Allow the welder to cool for at least 5 minutes before attempting to weld again 6 3 Spot welding with H 3000 Electronic Timer Adjust the welding time by using the control mounted on the rear of the unit See fig 6 9 6 4 SPOT WELDING PROCEDURE WARNING Ensure that you read and understand the safety instructions in Section 1 Use welder in a suitable working area Keep area clean a...

Отзывы: