INSTRUCTIONS FOR

GENERATOR 3800W 9.2HP 

MODEL NO: 

G3801

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY        

 

‰

  

WARNING!

 

Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment. 

 

9

   Familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.

 

9

   Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.  

  Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for  

  which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.

 

‰

   WARNING! DO NOT 

exceed the Wattage/Amperage capacity of the generator

.

 Add rated wattage of all devices intended for  

 

  connection at any one time, the total must not exceed rated wattage of generator (see specifications). 

 

‰

   WARNING! 

Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.

 

‰

   WARNING! 

If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),

        

it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the  

   

frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. This    

   

connection should only be attempted by a qualified electrician, after first having consulted your local dealer.

 

   DANGER! 

This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the 

          generator compartment of a caravan, may result in fire or an explosion. No user performed modifications, including venting of the    

   

exhaust and/or cooling ventilation, will eliminate the danger.

 

   DANGER! 

 If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.

          Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the  

   

commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a  

   

back-feed of electrical energy.

 

   DANGER! 

The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires,   

  terminals etc. Never allow any unqualified person to operate or service the generator.

 

‰

   WARNING! 

Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the vicinity  

  while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of fuels.

 

‰

   WARNING!

 Risk of burns. 

DO NOT

 touch the exhaust system or the drive unit.

 

‰

  

WARNING! NEVER

 refuel when the engine is running or when the engine is hot. Allow cool down time.

 

9

  

Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt  

  or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases). 

 

8

 

  DO NOT

 tip or change the generator’s position whilst it is operating.

 

9

  

Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.

 

9

  

Keep non-essential persons and children away from the working area.

 

‰

   WARNING!

 Never start or stop the generator while electrical loads are connected. Start the engine, let it stabilise, then connect the    

  electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching off.

 

‰

  

WARNING! 

Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in electric   

 shock.

 

8

  

DO NOT

 use the generator for any purpose other than that for which it is designed. 

 

8

  

DO NOT

 operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.

G3801 | Issue 1- 24/06/16

Original Language Version

© Jack Sealey Limited

Refer to instruction 

manual

Hot parts.

Keep your distance

Switch off the engine

Before refuelling

Never operate in 

Non-ventilated rooms

Содержание G3801

Страница 1: ...n fire or an explosion No user performed modifications including venting of the exhaust and or cooling ventilation will eliminate the danger DANGER If this unit is used for back up power in the event of a commercial power failure the following steps must be taken Before connecting the generator to the electrical system open the main circuit breaker to isolate the generator and system from the comm...

Страница 2: ...nk Fitted with one 230V 16A and one 110V 16A socket Powerful and reliable generator Smooth running unit fitted with anti vibration engine mounts Features low oil warning light overload protection and fuel gauge 3 SPECIFICATION Model no G3801 Motor power 9 2hp Motor type 4 stroke petrol Output 230V 50Hz Current rating 15 2 16A Continuous power rating 3500 1800W Maximum power rating 3800 2000W Fuel ...

Страница 3: ...G3801 Issue 1 24 06 16 Original Language Version Jack Sealey Limited 4 5 6 7 8 9 10 11 ...

Страница 4: ...or see fig 3 4 and the other end to an external earth for example an earthing rod 6 OPERATION Important You must fill up with engine oil approx 1 1ltr and fuel before you can start the engine See 7 4 and fig 10 Oil shortage light will illuminate if engine oil is low see fig 3 9A 6 1 Make sure that the generator has sufficient ventilation 6 2 Make sure that the ignition cable is secured to the spar...

Страница 5: ...he equipment regularly with a moist cloth and some soft soap Do not use cleaning agents or solvents these could attack the plastic parts of the equipment Ensure that no water can seep into the device 7 2 Air filter see figs 11 12 7 2 1 Clean the air filter at regular intervals and replace it if necessary 7 2 2 Open both clips see fig 11 A and remove the air filter cover see fig 11 B 7 2 3 Remove t...

Отзывы: