Sealey DPF1 Скачать руководство пользователя страница 2

3.  SPECIFICATION

MODEL NO.: ................................................................DPF1

Air receiving tank ............................................................15ltr

Air requirement ............................................................

4-6bar

Cleaning agent .........................................

Chemical/Water/Air

D

imensions (W x L x H)

 ........................

400 x 900 x 1120mm

Supply .................................................................

230V~50Hz

Power ................................................................................

5W

4.  CONTENTS

5.  OPERATION

5.1.    

DPF  PREPARATION

5.1.1.  

 

Select a suitable adaptor and gasket (fig.1-1, fig1-2, fig1-3) for the DPF. Ensure a good fit to the DPF to avoid spillage. Close off the  

 

adaptor using the Soaking Cap (fig.1.10). Block off any DPF pressure tappings.

5.1.2. 

  

Pour Ultra Clean detergent into inverted DPF and fill to the top  

 

face of the internal structure.

5.1.3. 

  

Leave the DPF in a vertical position for minimum of 30 minutes  

 

and regularly agitate it in order to ensure full coverage of solution  

 

within the DPF and to begin the cleaning effect.

5.1.4.   

Empty the contents into a suitable container after soaking the  

 

DPF for a suitable period.

5.2. 

  

OPERATION PREPARATION (fig.4)

5.2.1.   

Ensure that the unit is not connected to the power supply. 

5.2.2.   

Lay drained DPF onto machine bed ensuring the DPF outlet is  

 

beyond the brushes at the machine entrance. 

 NOTE:

 If the outlet of the DPF does not fit fully into the aperture 

 

 

on the machine, remove the cover by using the three  

 

 

thumbscrews on the face plate and fully engage the DPF into  

 

the exposed space.

 

NOTE: 

Some PDFs are not designed as ‘straight-through’ e.g.  

 

they may be ‘L’ or even ‘Z’ shaped. In certain circumstances it is  

 

advised to remove the aperture entrance cover, fit the discharge  

 

adaptor (fig.1.8) in place of the cover and attach the clear pipe  

 

(fig.1.6) between the adaptor and the DPF.

5.2.3. 

  

Strap DPF firmly to the machine bed using the supplied ratchet  

 

bars (fig.1.7).

5.2.4.   

Remove Soaking Cap from DPF and connect air supply to the  

 

adaptor fitted to the unit. 

5.2.5. 

  

Fill the water pressure container (fig1.11) with the appropriate  

 

amount of water that 

DOES NOT

 exceed the capacity of the  

 

waster bucket. 

5.2.6.    Connect the water supply fitting to the inlet of the air line fitting  

 

(fig.3). Ensure that the water outlet valve is closed at this stage.

 

NOTE: Ensure cover plate is placed with the arrow facing  

 

the machine entrance (see diagram right).

Original Language Version

© Jack Sealey Limited

   fig.1

Item 

No.

Part No.

Description

1

D

PF01.01

Adaptor 1 + Gasket

2

D

PF01.02

Adaptor 2 + Gasket

3

D

PF01.03

A

daptor 3 (Small Vehicle)

6

D

PF01.06

D

CS Clear Hydraulic Pipe (1-1/4”F to 

1-1/4”F) 1.5m

7

D

PF01.07

M

ini Ratchet Bar (25mm x 1.5m)

8

D

PF01.08

Discharge Adaptor (Small)

9

D

PF01.09 Waste Water Hose (38mm)

10

D

PF01.10

S

oaking Cap (1-1/4)

11

D

PF01.12 W

ater Pressure Container

12

D

PF01.13 Waste Water Bucket

D

PF1       Issue 2 (5)     23/09/20

Содержание DPF1

Страница 1: ...arth terminal E B Connect the BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING Ensure Health Safety local authority and general workshop practice regu...

Страница 2: ...the face plate and fully engage the DPF into the exposed space NOTE Some PDFs are not designed as straight through e g they may be L or even Z shaped In certain circumstances it is advised to remove the aperture entrance cover fit the discharge adaptor fig 1 8 in place of the cover and attach the clear pipe fig 1 6 between the adaptor and the DPF 5 2 3 Strap DPF firmly to the machine bed using the...

Страница 3: ...uency of operation The top dial controls the valve open time and measured in seconds while the lower dial sets valve close time and is measured in minutes When rinsing with water it is recommended to set open time to 0 1sec and close time to 0 1min and when air drying set open to 0 3sec and close to 0 3min Users may adjust these settings accordingly 5 4 3 Press Auto button fig 2 4 and the machine ...

Страница 4: ...ds according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually impro...

Отзывы: