4.1. 

Extending the cable.

4.1.1.  As the cable is pulled out from the reel the action of the ratchet mechanism can be heard alternating between the usual clicking  

 

 

sound and a short period of silence. If the tension on the cable is released whilst the ratchet is clicking the cable will remain extended.  

 

If the tension on the cable is released during the period of silence, the cable will retract. To stop the cable retracting, pull it out again a  

 

little until you hear the ratchet clicking.

4.2. 

Retracting the cable.

4.2.1.  To release the cable and allow it to automatically rewind, pull the cable out from the locked position until the clicking stops and then    

 

release the tension on the cable. Do not let go of the cable, but keep hold of it and guide the socket back to the reel.

 

WARNING!

 The reel tension is factory set, if any adjustment is required contact an authorised service agent. 

DO NOT remove any of  

 

the black spring cover screws. 

4.3. 

Thermal cut-out.

4.3.1.  In the event of the reel being overloaded, the cut-out will trip. If this occurs disconnect the reel from the mains supply and then  

 

 

determine and rectify the cause of the overload.

4.3.2.  Reconnect to the mains supply and press the cut-out reset button, after allowing two or three minutes for cooling.

4. OPERATION

3. MOUNTING/ASSEMBLY

3.1.

 

To wall mount the reel, first remove the wall mounting bracket from the reel by releasing and withdrawing the two bracket pivots. 

 

To release the pivots, remove the casing screws which pass directly through each pivot.

 Note:

 There are two screws attaching the top pivot. 

DO NOT 

remove any other casing screws.

3.2.

 

Fix the bracket in an appropriate position, ensuring that the wall and the mounting screws and plugs will adequately support the  

 

 

weight of the reel and the tension of the cable as it is pulled from the reel.

3.3.

 

Re-attach the reel to the bracket, ensuring that the pivots are correctly inserted and retained by the casing screws.

3.4.

 

Ensure that the cable can be pulled out to, and reeled back from, work sites without rubbing on the sides of the cable entry.

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

Original Language Version

CRM10.V5, CRM15.V5    Issue No:2(L) - 12/09/16

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, 

email [email protected] or phone 01284 757500.

Model No:

CRM10.V5

CRM15.V5

Input:

230V

230V

Output:

230V

230V

Power Wound/Unwound:

1000/2750W

1000/2750W

Cable Length:

10m

15m

Cable Size:

3 x 1.5mm²

3 x 1.5mm²

Thermal Cut-out:

Yes

Yes

2.  TECHNICAL SPECIFICATIONS