fig.5

fig.7

 1   2      3              4               5                             6                                     7              8          9                t 

Lead acid battery charge graphical representation

u(V)

i (A)

Charging stages

 (9 steps)

1  - Qualification

2  - Battery recovery

3  - Soft start

4  - Pulse mode

5  - Recondition

6  - Bulk

7  - Absorption

8  - Equalisation

9  - Check

t

To select charging mode or re-set during charging.

A single press of the button moves to next mode.

Mode : 14.4V 25.0A or 28.8V 12.5A. This mode is 

normally used for all types of  batteries. On 

selection the charger cooling fan starts.
Mode : 14.7V 25A or 29.4V 12.5A. This setting is 

recommended at temperatures below 5°C. Not 

recommended when temperatures exceed 5°C. 

Mode : Calcium select for all calcium batteries. Also

batteries with voltages below 10.5V without

capacity to absorb charging current. The charger 

will automatically pulse charge up to 16V to recover 

battery. If the battery cannot be recovered after 2 

hours a fault (!) icon will illuminate. New battery 

required.  

Mode : DC supply (13.5V 25A) Provides support for 

the battery during prolonged electronic diagnostic 

checks.

Select the required voltage. A single press of the 

button will change voltage illuminating a green 

indicator.

!

Voltage

Current

Charging %

Press display button once to illuminate Voltage, press 

again to illuminate Current, press again to illuminate 

Charging %. Read values in the LED window. 

When the exclamation mark indicator illuminates, it is 

accompanied by a high pitched audible alarm. A fault 

condition has been detected and will be identified in 

the LED window as F 0 1, F 0 2, F 0 3, F 0 4 and 

F 0 5, see section 6 "TROUBLE SHOOTING". 

Read values in the LED window. 

Read values in the LED window. 

Read values in the LED window. 

Digital LED display to show Voltage, Current, and 

Charging %. It will also display status, functions and

fault conditions. See section on Trouble Shooting.  

fig.6

© Jack Sealey Limited 2013

 

display

12V

24V

MODE

Cal

Содержание BSCU25

Страница 1: ...ical safety contact a qualified electrician 1 1 3 DO ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply See 1 2 1 above and use a Portable Appliance Tester PAT 1 1 4 DO ensure that cables are always protected against short circuit and overload 1 1 5 DO regularly inspect power supply leads plugs for wear and damage and all electrical conne...

Страница 2: ... start an engine or to charge a battery if the battery is frozen In prolonged extremely cold conditions a battery could become frozen A frozen battery could explode if charged Cold cranking will put additional strain on the engine and the battery WARNING To prevent the risk of sparking short circuit and possible explosion DO NOT drop metal tools in the battery area or allow them to touch the batte...

Страница 3: ... the snowflake icon indicates low temperature environment charging the Cal indicates calcium type battery charging and is also a repair mode for sulphated batteries The battery clips icon indicate battery support mode this mode provides power for the battery during prolonged electronic diagnostic checks If either the Cal icon or the battery clip icon mode is required from the initial flashing 000 ...

Страница 4: ...cover battery If the battery cannot be recovered after 2 hours a fault icon will illuminate New battery required Mode DC supply 13 5V 25A Provides support for the battery during prolonged electronic diagnostic checks Select the required voltage A single press of the button will change voltage illuminating a green indicator Voltage Current Charging Press display button once to illuminate Voltage pr...

Страница 5: ...ery Charger internal temperature too high Battery fully charged Voltage held until power removed 1 Reconnect terminal 2 Check all connections 3 Reverse connections Check connections and start charging process again Battery voltage not as voltage setting Start charging again if fault condition reoccurs replace battery Cooling fan not working Ambient temperature too high 40 C Standby status 5 1 Afte...