Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. iP32 7Ar
01284 757500
01284 703534
www.sealey.co.uk
ENVirONMENT PrOTEcTiON
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE rEGUlATiONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note
: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on [email protected] or 01284 757505.
important
: No Liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
5.
.
MAiNTENANcE
5.1.
After each use clean the charger clamps, removing corrosive battery fluids.
5.2.
Clean the charger casing and charger leads with a soft cloth and mild detergent solution.
5.3.
Keep the charger leads loosely coiled during storage without snagging or crushing.
8
DO NOT
attempt to repair damaged leads, these must be replaced by your Sealey service agent or a qualified person.
8
DO NOT
attempt to repair charger electronics, this must be done by your Sealey service agent or a qualified person.
6. TrOUBlESHOOTiNG
cODES
DEScriPTiON
TrOUBlESHOOTiNG
Standby status.
Check battery status before
charging.
B
attery already fully charged.
Charger is repairing battery.
Temporary indication of start.
Repair mode for sulphated
batteries.
1) No connection to battery.
2) Short circuit.
3) Reversed polarity connection.
1) Reconnect terminal.
2) Check all connections.
3) Reverse connections.
Clip loosened during charging. The
charger stops, an audible alarm will
sound in 25 secs.
Check connections and start
charging process again.
B
attery voltage too high.
B
attery voltage not as voltage
setting.
Current leakage inside battery.
Start charging again, if fault
condition re-occurs, replace battery.
Charger internal temperature too
high.
Cooling fan not working. Ambient
temperature too high, (40°C).
Battery fully charged. Voltage held
until power restored.